![Vaillant VRT 360f Operating and Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/vaillant/vrt-360f-operating-and/vrt-360f-operating-and_operating-and-installation-manual_848962010.webp)
10
Operating manual
VRT 360f
Symbol
Meaning
Heating
Hot water
Automatic:
The operation of the heating circuit changes between
the operation modes Heating and Energy Saving
. The heating circuit symbol is displayed if a heating
requirement is detected.
The operation of the hot water
storage cylinder/circulation
pump changes between
heating/ON
and OFF
depending upon the time
programme set on the room
temperature thermostat.
The hot water symbol and the
circulation pump symbol are
displayed if the time window
is active.
Heating:
The heating circuit is operated according to the
room temperature, regardless of the programme set
on the room temperature thermostat. The heating
circuit symbol is displayed if a heating requirement is
detected.
Energy Saving:
The heating circuit is operated according to the
energy saving temperature "ECO“, regardless of the
programme set on the room temperature thermostat.
The heating circuit symbol is displayed if a heating
requirement is detected.
Table 4.1 Operating modes