Vaillant VR 70 Скачать руководство пользователя страница 5

Notes on the documentation 2

0020198787_00 VR 70 Installation instructions

5

2

Notes on the documentation

2.1

Observing other applicable documents

You must observe all the operating and installation in-
structions included with the system components.

2.2

Storing documents

Pass these instructions and all other applicable docu-
ments on to the system operator.

2.3

Applicability of the instructions

These instructions apply only to:

VR 70

Article number

Great Britain

0020184844

3

Product overview

3.1

CE label

The CE label shows that the products comply with the basic
requirements of the applicable directives as stated on the
identification plate.

The declaration of conformity can be viewed at the manufac-
turer's site.

3.2

Design of the product

3

4

1

2

1

Wall-mounting base

2

Diagnostics socket

3

Front casing

4

Front panel for the
fixing screw

3.3

How it works

The product has inputs and outputs. By assigning the inputs
and outputs in different ways, you can set up various sys-
tems. The inputs and outputs are configured using the con-
troller.

3.4

Identification plate

The identification plate is located on the right-hand side of
the casing.

Information on the identific-
ation plate

Meaning

Serial number

For identification

VR 70

Product description

V

Operating voltage

W

Power consumption

Switching capacity for each
relay and overall switching
capacity

Product complies with
European standards and
directives

Proper disposal of the product

3.5

Checking the scope of delivery

Quantity

Component

1

VR 70

2

VR 10

1

Installation accessories (bolts and rawl plugs)

1

Installation instructions

Check that the scope of delivery is complete.

Содержание VR 70

Страница 1: ...person Installation instructions VR 70 GB IE Installation instructions Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Telefon 021 91 18 0 Telefax 021 91 18 28 10 info vaillant de www vaillant de ...

Страница 2: ...ntation 5 2 1 Observing other applicable documents 5 2 2 Storing documents 5 2 3 Applicability of the instructions 5 3 Product overview 5 3 1 CE label 5 3 2 Design of the product 5 3 3 How it works 5 3 4 Identification plate 5 3 5 Checking the scope of delivery 5 4 Installation 6 5 Electrical installation 6 5 1 Setting the bus address 7 6 Decommissioning 7 7 Recycling and disposal 8 8 Customer ser...

Страница 3: ...V lines Use sheathed cables for 230 V lines e g NYM 3 x 1 5 Minimum cross section Supply line 230 V pump or mixer mains cable 1 5 mm eBUS line extra low voltage 0 75 mm Sensor line extra low voltage 0 75 mm Maximum line length Sensor lines 50 m Bus lines 125 m 1 3 Regulations directives laws standards Observe the national regulations stand ards guidelines and laws 1 4 Intended use In the event of ...

Страница 4: ...1 Safety 4 Installation instructions VR 70 0020198787_00 use Any direct commercial or industrial use is also deemed to be improper Caution Improper use of any kind is prohibited ...

Страница 5: ...te 3 2 Design of the product 3 4 1 2 1 Wall mounting base 2 Diagnostics socket 3 Front casing 4 Front panel for the fixing screw 3 3 How it works The product has inputs and outputs By assigning the inputs and outputs in different ways you can set up various sys tems The inputs and outputs are configured using the con troller 3 4 Identification plate The identification plate is located on the right...

Страница 6: ... electrical components that are connected to the low voltage network Disconnect the product from the power supply Secure the product against being switched back on again Check that the product is de energised Only open the product when it is de ener gised R2 L N R1 L N 230V L N BUS R5 6 1 2 N R3 4 N 1 2 S1 1 2 S2 1 2 S3 1 2 S4 1 2 S5 1 2 S6 1 2 S7 O I 5 1 4 4 5 2 3 1 Input 2 Input and output 3 eBU...

Страница 7: ...ler s wall socket Connecting the line to the lower terminal block B E D C 25 mm A 6 Connect all of the required lines in accordance with the illustration 7 Set the bus address Page 7 8 Close the product Page 6 5 1 Setting the bus address BUS S2 1 2 S3 1 2 S4 1 2 S5 1 2 S6 1 2 S7 O I 1 1 1 Address switch Assign a unique address to each VR 70 that is connec ted beginning with Address 1 6 Decommissio...

Страница 8: ... that are marked with this symbol these batteries may contain substances that are hazardous to human health and the environment In this case dispose of the batteries at a collection point for batteries 8 Customer service To ensure regular servicing it is strongly recommended that arrangements are made for a Maintenance Agreement Please contact Vaillant Service Solutions 0870 6060 777 for further d...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ...nt Service Solutions 44 807 06 06 07 77 Spares Technical Enquiries 44 17 73 59 66 15 info vaillant co uk technicalspares groupservice co uk www vaillant co uk These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer s written consent 2703693_rev0 ...

Отзывы: