Vaillant VR 70 Скачать руководство пользователя страница 3

Safety 1

0020198787_00 VR 70 Installation instructions

3

1

Safety

1.1

General safety information

1.1.1 Risk of death from live connections

There is a risk of death from electric shock
when working on the product when it is open.

Switch the main switch off before removing
the cover to work on the product.

Disconnect the product from the power
mains by de-energising the product using
a partition with a contact opening of at
least 3 mm (e.g. fuses or power switches).

Check that the product is de-energised.

Secure the power supply against being
switched on again.

1.1.2 Material damage due to unsuitable

installation room

If you are installing the product in a moist en-
vironment, the electronics may be damaged
by moisture.

Only install the product in dry rooms.

1.1.3 Danger due to error functions

Ensure that the heating system is in a
technically perfect condition.

Ensure that no safety or monitoring
devices have been removed, bridged or
disabled.

Immediately rectify any faults and damage
that may affect safety.

At lengths of over 10 m, 230 V supply
cables must be laid separately from sensor
or bus lines.

Secure all supply lines in the casing using
the enclosed strain relief.

Do not use the unit's free terminals as sup-
ports for other wiring.

1.2

Requirements for lines

Use standard commercial lines for the wir-
ing.

Do not use flexible lines for 230 V lines.

Use sheathed cables for 230 V lines (e.g.
NYM 3 x 1.5).

Minimum cross-section

Supply line 230 V (pump or
mixer mains cable)

1.5 mm

²

eBUS line (extra-low
voltage)

0.75 mm

²

Sensor line (extra-low
voltage)

0.75 mm

²

Maximum line length

Sensor lines

50 m

Bus lines

125 m

1.3

Regulations (directives, laws,
standards)

Observe the national regulations, stand-
ards, guidelines and laws.

1.4

Intended use

In the event of inappropriate or improper use,
damage to the product and other property
may arise.
This product is a system component that en-
hances the system's functionality. A controller
controls and regulates the functions via an
eBUS interface.
Operation is permissible with the following
component:

VRC 700

Intended use includes the following:

observance of accompanying operating,
installation and servicing instructions for
the product and any other system compon-
ents

compliance with all inspection and main-
tenance conditions listed in the instruc-
tions.

This product can be used by children over
eight years old and also by persons with lim-
ited physical, sensory or mental capabilities
or insufficient experience and/or knowledge if
they are supervised or have been provided
with instructions on how to safely use the
product, and they understand the risks res-
ulting from using the product. Children must
not play with the product. Cleaning and user
maintenance work must not be carried out by
children unless they are supervised.
Any other use that is not specified in these
instructions, or use beyond that specified in
this document shall be considered improper

Содержание VR 70

Страница 1: ...person Installation instructions VR 70 GB IE Installation instructions Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Telefon 021 91 18 0 Telefax 021 91 18 28 10 info vaillant de www vaillant de ...

Страница 2: ...ntation 5 2 1 Observing other applicable documents 5 2 2 Storing documents 5 2 3 Applicability of the instructions 5 3 Product overview 5 3 1 CE label 5 3 2 Design of the product 5 3 3 How it works 5 3 4 Identification plate 5 3 5 Checking the scope of delivery 5 4 Installation 6 5 Electrical installation 6 5 1 Setting the bus address 7 6 Decommissioning 7 7 Recycling and disposal 8 8 Customer ser...

Страница 3: ...V lines Use sheathed cables for 230 V lines e g NYM 3 x 1 5 Minimum cross section Supply line 230 V pump or mixer mains cable 1 5 mm eBUS line extra low voltage 0 75 mm Sensor line extra low voltage 0 75 mm Maximum line length Sensor lines 50 m Bus lines 125 m 1 3 Regulations directives laws standards Observe the national regulations stand ards guidelines and laws 1 4 Intended use In the event of ...

Страница 4: ...1 Safety 4 Installation instructions VR 70 0020198787_00 use Any direct commercial or industrial use is also deemed to be improper Caution Improper use of any kind is prohibited ...

Страница 5: ...te 3 2 Design of the product 3 4 1 2 1 Wall mounting base 2 Diagnostics socket 3 Front casing 4 Front panel for the fixing screw 3 3 How it works The product has inputs and outputs By assigning the inputs and outputs in different ways you can set up various sys tems The inputs and outputs are configured using the con troller 3 4 Identification plate The identification plate is located on the right...

Страница 6: ... electrical components that are connected to the low voltage network Disconnect the product from the power supply Secure the product against being switched back on again Check that the product is de energised Only open the product when it is de ener gised R2 L N R1 L N 230V L N BUS R5 6 1 2 N R3 4 N 1 2 S1 1 2 S2 1 2 S3 1 2 S4 1 2 S5 1 2 S6 1 2 S7 O I 5 1 4 4 5 2 3 1 Input 2 Input and output 3 eBU...

Страница 7: ...ler s wall socket Connecting the line to the lower terminal block B E D C 25 mm A 6 Connect all of the required lines in accordance with the illustration 7 Set the bus address Page 7 8 Close the product Page 6 5 1 Setting the bus address BUS S2 1 2 S3 1 2 S4 1 2 S5 1 2 S6 1 2 S7 O I 1 1 1 Address switch Assign a unique address to each VR 70 that is connec ted beginning with Address 1 6 Decommissio...

Страница 8: ... that are marked with this symbol these batteries may contain substances that are hazardous to human health and the environment In this case dispose of the batteries at a collection point for batteries 8 Customer service To ensure regular servicing it is strongly recommended that arrangements are made for a Maintenance Agreement Please contact Vaillant Service Solutions 0870 6060 777 for further d...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ...nt Service Solutions 44 807 06 06 07 77 Spares Technical Enquiries 44 17 73 59 66 15 info vaillant co uk technicalspares groupservice co uk www vaillant co uk These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer s written consent 2703693_rev0 ...

Отзывы: