background image

System and product description

18

Operating and installation instructions 0020248967_00

3

Flashing 
sequence

Meaning

Required 
activity

Long and 
brief period 
of flashing 
orange (alter-
nating)

Update to the 
unit software 
(OTAU = Over 
the Air 
Update)

New software 
is trans-
ferred. (Dura-
tion: Up to 12 
hours) This 
does not 
affect how 
the product 
works during 
this time.

3.7 

Duty cycle limit

The duty cycle limit describes a legally 
regulated limit on the transmission time of 
units in the 868 MHz range. The aim of 
this regulation is to guarantee that all 
units that work in the 868 MHz range 
work correctly. In the frequency range 868 
MHz that is used by the product, the maxi-
mum transmission time for each individual 
unit is 1% of an hour (i.e. 36 seconds in 

Содержание VR 50

Страница 1: ...g and installation instructions GB IE Radiator thermostat VR 50 Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www vai...

Страница 2: ...cuments 9 2 3 Validity of the instructions 9 3 System and product description 10 3 1 Component of the ambiSENSE system 10 3 2 Design of the product 12 3 3 Display 13 3 4 Window opening detector 14 3 5...

Страница 3: ...operating mode 34 7 2 Setting the temperature 34 7 3 Using the Boost function 35 7 4 Activating deactivating the operation lock 36 8 Troubleshooting 36 8 1 Command not confirmed 36 8 2 Fault messages...

Страница 4: ...arnings The action related warnings are classified in accordance with the severity of the pos sible danger using the following warning signs and signal words Warning symbols and signal words a Danger...

Страница 5: ...the event of inappropriate or improper use damage to the product and other property may arise You can use the radiator thermostat for the time controlled regulation of common radiator valves from the...

Страница 6: ...tion and servicing instructions for the product and any other system components installing and fitting the product in accordance with the product and sys tem approval compliance with all inspection an...

Страница 7: ...of any kind is prohibited 1 3 General safety information 1 3 1 Danger caused by improper operation Improper operation may present a danger to you and others and cause material damage Carefully read t...

Страница 8: ...aused by unsuitable environmental conditions The electronics may be damaged if you install the product in an unsuitable envi ronment Only install the product in dry dust free rooms Ensure that the pro...

Страница 9: ...pplicable documents You must observe all the operating and installation instructions included with the system components 2 2 Storing documents Keep this manual and all other applica ble documents safe...

Страница 10: ...io protocol All products in the ambiSENSE room climate solution can be configured using the VRC 700 app on a smartphone You can use the radiator thermostat for the time controlled regulation of the ta...

Страница 11: ...mensions of M30 x 1 5 mm Using the adapter that is included in the scope of delivery means that the product can also be installed on Danfoss RA Danfoss RAV and Danfoss RAVL radiator valves The product...

Страница 12: ...product description 12 Operating and installation instructions 0020248967_00 3 3 2 Design of the product 5 1 2 3 4 1 Knurled nut 2 Display 3 System button with signal LED 4 Battery compartment 5 Sett...

Страница 13: ...48967_00 13 3 3 3 Display i Note The background lighting for the dis play is switched off in Standby mode To activate the background lighting press the setting wheel once VALVE adapt VALVE install MAN...

Страница 14: ...is open e g for ventila tion the system automatically lowers the temperature in order to save heating energy and costs No window sensor is required for this function This function is implemented in th...

Страница 15: ...fore not be ruled out Interfer ences may for example be caused by switching operations electric motors or defective electrical units The range inside buildings may differ con siderably from the range...

Страница 16: ...ns mission transmission attempt data transmission Wait until the transmission has ended 1 x long period of lighting up green Process con firmed Continue with the opera tion 1 x long period of lighting...

Страница 17: ...d of lighting up orange after a green or red reception notification Batteries flat Replace the batteries 3 x long period of flashing red Product defective Note the dis play in the App or con tact the...

Страница 18: ...Dura tion Up to 12 hours This does not affect how the product works during this time 3 7 Duty cycle limit The duty cycle limit describes a legally regulated limit on the transmission time of units in...

Страница 19: ...system increased and radio intensive pair ing processes may mean that this limit is not reached If the duty cycle limit is exceeded the signal LED lights up red for one extended period and may indicat...

Страница 20: ...2014 53 EU The complete text for the EU Declaration of Conformity is available at http www vaillant group com doc doc radio equipment directive 3 9 Checking the scope of delivery Check that the scope...

Страница 21: ...ctions 4 Integration into the ambiSENSE system 4 1 Pairing To ensure that the product is integrated into the ambiSENSE system and can com municate with other ambiSENSE units it must first be paired to...

Страница 22: ...en the installation assistant in the app requests that you establish the power supply open the product s bat tery compartment and pull the insulat ing strips out of the battery compart ment The motor...

Страница 23: ...tphone to scan the QR code i Note You can find the unit number and the QR code on the enclosed sticker and in the product s battery com partment Wait until the pairing process is com plete The signal...

Страница 24: ...installation instructions 0020248967_00 5 5 Set up 5 1 Installing the radiator thermostat C A B 1 Turn the thermostat head anti clockwise to the maximum value The thermostat head is now no longer pus...

Страница 25: ...on nuts Loosen the union nuts in an anti clock wise direction and remove the thermo stat head Conditions Fastening with snap on mounts Turn the union nuts slightly in an anti clockwise direction and r...

Страница 26: ...ng with set screws Undo the set screw and remove the thermostat head 3 Start the pairing process in the App Page 4 4 Install the product when you are requested to do so in the App during the pairing p...

Страница 27: ...nstructions 0020248967_00 27 5 A B 6 Use the knurled nut on the radiator valve to install the new radiator thermo stat 5 2 Installing the radiator thermostat with Danfoss adapter 1 Remove the old ther...

Страница 28: ...enclosed adapter for the installation on Danfoss radiator valves Conditions Danfoss RA radiator valve A B 1 2 During the installation ensure that the pins inside the adapter 2 are congru ent to the r...

Страница 29: ...closed screw and nut to secure the adapter Conditions Danfoss RAV radiator valve A B 3 1 2 Before the installation mount the tap pet extension 2 onto the valve pin During the installation ensure that...

Страница 30: ...p the adapter that is suitable for the valve fully into place Use the enclosed screw and nut to secure the adapter Conditions Danfoss RAVL radiator valve 2 1 During the installation ensure that the pi...

Страница 31: ...tallation instructions 0020248967_00 31 5 Snap the adapter that is suitable for the valve fully into place i Note The RAVL adapter is not screwed in 3 Use the knurled nut on the adapter to install the...

Страница 32: ...ns 0020248967_00 5 5 3 Installing the radiator thermostat with support ring 1 If the diameter of the part of the radia tor valve that projects into the radiator thermostat is too small place the sup p...

Страница 33: ...tive run by pressing the setting wheel During the adaptive run Valve adapt is shown on the display i Note No other operation is possible dur ing the adaptive run After a suc cessful adaptive run the d...

Страница 34: ...p The temperature setting is retained until the next time a manual change is implemented Press and hold the setting wheel to switch between manual mode and auto matic mode 7 2 Setting the temperature...

Страница 35: ...here In manual mode the temperature is retained until the next time a manual change is implemented Turn the setting wheel clockwise or anticlockwise to manually increase or decrease the temperature of...

Страница 36: ...operation lock 8 Troubleshooting 8 1 Command not confirmed If at least one transceiver does not con firm a command the signal LED lights up red once the incorrect transmission is completed The reason...

Страница 37: ...mperature display Fault Possible cause Remedy F1 Valve drive stiff Check whether the tappet for the heat ing valve is jammed F2 Setting range too big Check the fastening for the radiator thermostat F3...

Страница 38: ...0020248967_00 8 flashes Communica tion fault to the Internet gateway and or to the repeater Check the connec tion to the Internet gateway and or to the repeater 8 3 Resetting to factory setting i Not...

Страница 39: ...batteries in accordance with the polarity markings and at the same time press and hold the system button for four seconds until the signal LED starts to rapidly flash in orange 3 Release the system bu...

Страница 40: ...0 Operating and installation instructions 0020248967_00 9 5 Release the system button The product restarts 9 Care and maintenance 9 1 Caring for the product Clean the casing with a damp cloth and a li...

Страница 41: ...tallation instructions 0020248967_00 41 9 9 2 Changing batteries A B 1 Open the battery compartment as shown in the figure 2 Always change all the batteries at the same time Battery type LR06 Mignon A...

Страница 42: ...A B 4 Insert the batteries making sure that the poles are the right way round After inserting the batteries the product runs through a self test for approx two seconds Initialisation then takes place...

Страница 43: ...test successful Signal LED lights up orange first and then green Close the battery compartment 9 2 1 Risk of death caused by unsuitable batteries a Danger Risk of death caused by unsuitable batteries...

Страница 44: ...battery type when replacing batteries Dispose of used batteries in accordance with the instruc tions in this manual 9 2 2 Leaking batteries a Danger Risk of chemical burns caused by leaking batteries...

Страница 45: ...protective gloves 9 2 3 Batteries Note the battery type as described in these instructions see section Data plate Remove and insert batteries as described in these instructions see section Changing th...

Страница 46: ...t and dispose of them correctly Remove the batteries if you intend to store the product and not use it for an extended period and or to scrap it Do not short circuit the connection con tacts in the pr...

Страница 47: ...ad hand in the product to a collec tion centre for old electrical or elec tronic appliances If the product contains batteries that are labelled with this mark these bat teries may contain substances t...

Страница 48: ...ype 2 x 1 5 V LR6 Mignon AA Current consumption 120 mA Battery life 2 years IP rating IP 20 Degree of contamina tion 2 Permissible environmental temperature 0 50 C Height 71 mm 2 80 in Width 58 mm 2 2...

Страница 49: ...allation instructions 0020248967_00 49 12 Parameter Value Maximum transmission power 25 mW Receiver category SRD category 2 Range outdoors 300 m 984 ft 3 in Duty Cycle 1 per h 10 per h Mode of operati...