background image

Vaillant-Witte

®

Elektro-Raumheizer

Vaillant-Witte

®

Independent Room Heaters

VER 75/3, VER 100/3, VER 150/3, VER 200/3, VER 250/3

INSTALLATIONS- UND BEDIENUNGSANLEITUNG

INSTALLATION AND OPERATING INSTRUCTIONS

Содержание VER 75/3

Страница 1: ...Vaillant Witte Elektro Raumheizer Vaillant Witte Independent Room Heaters VER 75 3 VER 100 3 VER 150 3 VER 200 3 VER 250 3 INSTALLATIONS UND BEDIENUNGSANLEITUNG INSTALLATION AND OPERATING INSTRUCTIONS ...

Страница 2: ...itial start up only by a qualified contractor Guarantee will only be valid if the appliance has been installed and started up initially by an approved contractor who is responsible for the observance of applicable standards and installation instructions We do not accept responsability for damage arising from the non observance of these instruction 1 Application Universal independant room heaters w...

Страница 3: ... be installed underneath a wall socket outlet The room heater must not be permanently wired to the mains The appliance must be installed in the bathroom in such a way that switches regulating and control elements cannot be touched by a person using the bath or the shower Important The housing temperature exceeds 60 C There is a danger of fire See warning notice on the appliance Never cover the hea...

Страница 4: ...he line connection has to be accessible The installation and electrical connection of the heater must be carried out by an approved skilled person 3 Installation Wall mounting The heater must be mounted vertically see fig 2 1 page 8 Fix the appliance bracket to the wall as shown in the installation sketch fig 3 1 and 3 2 using the enclosed installation materials See fig 3 1 on page 9 for installat...

Страница 5: ...ied out by an approved contractor Only use original Vaillant special purpose cables 5 Starting up Set the switch 3 to position I The built in room thermostat keeps the required room temperature constant If a room which is not being used is to be protected against frost set the ther mostat knob 2 to position 5 1 Switch 3 The heater is switched off when the O marking is visible Involuntary control i...

Страница 6: ... 6206 6207 6208 6209 Anschlußwert 0 75 kW 1 00 kW 1 50 kW 2 00 kW 2 50 kW connected load Spannung 1 N PE 230 V Voltage Frostschutz ca 4 C frost protection Abmessungen Dimensions Höhe height 430 mm 430 mm 430 mm 430 mm 430 mm Breite width 340 mm 420 mm 580 mm 740 mm 900 mm Tiefe depth 85 mm 85 mm 85 mm 85 mm 85 mm Wandabstand 20 mm dist from wall Anschlußkabel 1 m Anschlußkabel 1 m mit Euro Winkels...

Отзывы: