![Vaillant VAM 6-050 W2N Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/vaillant/vam-6-050-w2n/vam-6-050-w2n_installation-manual_3282656020.webp)
18
VAM 6 MWN-I_EN - 09/14 - Vaillant
INSTALLATION
11.5
Electrical characteristics
Fig. 11.3
Electrical layout for outdoor and indoor connection.
Legend
1
Connector strip for the outdoor unit
2
Connector strip for the indoor unit
A + B
VAM 6-050 W2N / VAM 6-060 W2N
A + B + C
VAM 6-085 W3N
A + B + C + D
VAM 6-085 W4N
VAM 6-050 W2N
VAM 6-060 W2N
VAM 6-085 W3N
VAM 6-085 W4N
Power supply (V/Ph/Hz)
220-240V / 1 / 50
220-240V / 1 / 50
220-240V / 1 / 50
220-240V / 1 / 50
Supply
Supply section up to 25 meter (in mm
2
)
2.5
2.5
4
4
Indoor / Outdoor
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Thermal-magnetic circuit breaker, type D (A)
20
20
25
25
Interconnection section up to 25 meter (mm
2
)
2.5
2.5
2.5
2.5
Inteconnect shielded cable or not (YES / NO)
NO
NO
NO
NO
Immediatte residual current protector (A)
0.03
0.03
0.03
0.03
Table 11.1