VAI3-WN-I_EN - 07/14 - Vaillant
- 24 -
TECHNICAL DATA
Outdoor unit
VAI 3-025 WNO
VAI 3-035 WNO
VAI 3-050 WNO
Indoor Unit
VAI 3-025 WNI
VAI 3-035 WNI
VAI 3-050 WNI
Heating
(Average climate)
TOL
Tol (temperature operating limit) °C
-10
-10
-10
Pdh (declared heating cap)
kW
2,4
3
4,3
COPd (declared COP)
2,6
2,4
2,4
TBivalent
Tbiv (bivalent temperature)
°C
-7
-7
-7
Pdh (declared heating cap)
kW
2,4
3,1
4,72
COPd (declared COP)
2,3
2,4
2,6
A Condition
(-7°C)
Pdh (declared heating cap)
kW
2,4
3,1
4,72
COPd (declared COP)
2,3
2,4
2,6
B Condition
(2°C)
Pdh (declared heating cap)
kW
1,5
1,9
2,87
COPd (declared COP)
4,1
3,7
3,8
C Condition
(7°C)
Pdh (declared heating cap)
kW
0,9
1,2
1,85
COPd (declared COP)
4,9
5,2
4,8
D Condition
(12°C)
Pdh (declared heating cap)
kW
0,9
0,9
0,82
COPd (declared COP)
6,4
5,9
5,5
Pto (Thermostat off)(Cooling/Heating)
kW
0.035 / 0.012
0.039 / 0.01
0.05 / 0.013
Cooling
Psb (Standby mode cooling)
kW
0,001
0,001
0,0012
Pcycc
kW
NA *
NA *
NA *
EERcyc
NA *
NA *
NA *
Cdc (Degradation cooling)
0,25
0,25
0,25
Pck (Crankcase heater mode)
kW
NA *
NA *
NA *
Poff (Off mode)
kW
NA *
NA *
NA *
Heating
Psb (Standby mode heating)
kW
0,001
0,001
0,0012
Pcych
kW
NA *
NA *
NA *
COPcyc
NA *
NA *
NA *
Cdh (Degradation heating)
0,25
0,25
0,25
Table 14.1 Additional datasheet.
* We have different sound level datas according to different air flow volume or
frequencies, not according to the working temp.
i
NOTE:
As part of its policy for ongoing improvements of its
products, Vaillant reserves the right to modify these
specifications without prior notice.