![Vaillant sensoHOME VRT 380 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/vaillant/sensohome-vrt-380/sensohome-vrt-380_operating-and-installation-instructions_848787011.webp)
Product description 2
0020288192_00
sensoHOME
Operating and installation instructions
9
MENU
→
SETTINGS
→
Installation con-
figuration
Functions (
→
Installation configuration
menu item)
→
Screed drying
Activate the
Screed drying profile
function for freshly laid screed in
accordance with the construction regulations.
The system control regulates the flow temperature independently of
the outdoor temperature. Setting screed drying (
→
Installation config-
uration
menu item)
→
Change code
→
Language, time, display
→
Language:
→
Date:
After the power is switched off, the date is retained for approx. 30
minutes.
→
Time:
After the power is switched off, the time is retained for approx. 30
minutes.
→
Display brightness:
→
Daylight saving
time:
→
Automatic
→
Manual
The change takes place:
–
On the last weekend in March at 02:00 (daylight saving time)
–
On the last weekend in October at 03:00 (standard time)
→
Offset
→
Room temperat-
ure: K
Comparison of the temperature difference between the measured
value in the system control and the value for a reference thermometer
in the living room.
→
Outdoor temper-
ature: K
Comparison of the temperature difference between the measured
value in the outdoor temperature sensor and the value for a reference
thermometer in the living room.
→
Factory settings
The system control resets all of the settings to the factory settings and
calls up the installation assistant.
Only the competent person can call up the installation assistant.
2.10.4
Installation configuration menu item
MENU
→
SETTINGS
→
Installer level
→
Installation configuration
→
Installation
→
Water pressure: bar
→
eBUS components
List of eBUS components and their software versions
→
Adaptive heat curve:
Automatic fine adjustment of the heat curve. Prerequisite:
–
The suitable heat curve for the building is set in the
Heat
curve:
function.
–
The correct zone is assigned to the system control or the
remote control in the
Zone assignment:
function.
–
Expanded
is selected in the
Room temp. mod.:
function.
R.temp.contr
It
is
controlled
via
the
room
temperature.
→
Control:
Содержание sensoHOME VRT 380
Страница 17: ... Electrical installation set up 3 0020288192_00 sensoHOME Operating and installation instructions 15 A B 3 ...
Страница 40: ...3 Instalación eléctrica montaje 38 Manual de uso e instalación sensoHOME 0020288192_00 A B 3 ...
Страница 62: ...3 Instalação elétrica montagem 60 Instruções de uso e instalação sensoHOME 0020288192_00 A B 3 ...
Страница 84: ...3 Električna napeljava montaža 82 Navodila za uporabo in namestitev sensoHOME 0020288192_00 A B 3 ...
Страница 94: ...92 Country specifics VRT 380 0020288192_00 ...
Страница 95: ...0020288192_00 VRT 380 Country specifics 93 ...