Product description 2
0020288151_00
sensoCOMFORT
Operating and installation instructions
63
2.12
Operating and display functions
Note
The functions described in this section are not available for all system configurations.
The product has two adjustment and display levels.
The end user level contains information and setting options that you require as the end user.
The installer level is reserved for the competent person. It is protected by a code. Only competent persons may change
any settings in the installer level.
To call up the menu, press
twice.
2.12.1 CONTROL menu item
MENU
→
CONTROL
→
Zone
→
Name of zone
Changing the name
Zone 1
, which was set at the factory
→
Heating
→
Mode:
→
Manual
→
Desired temperature: °C
Uninterrupted retention of the desired temperature
→
Time-contr.
→
Weekly planner
→
Set-back temperature: °C
Weekly planner
: Up to 12 time periods and desired temperatures can be set per day
The competent person sets how the heating installation behaves outside of the time period in the
Set-back mode:
function.
In
Set-back mode:
means:
–
Eco
: The heating is switched off outside of the time periods. Frost protection is activated.
–
Normal
: The set-back temperature applies outside of the time periods.
Desired temperature: °C
: Applies within the time periods
→
Off
Heating is switched off, domestic hot water continues to be available, frost protection is activated
→
Cooling
→
Mode:
→
Manual
→
Desired temperature: °C
Uninterrupted retention of the desired temperature
→
Time-contr.
→
Weekly planner
→
Desired temperature: °C
Weekly planner
: Up to 12 time periods can be set per day; cooling is switched off outside of the
time periods
Desired temperature: °C
: Applies within the time periods
Cooling is switched off outside of the time periods
→
Off
Cooling is switched off, domestic hot water remains available
→
Absence
→
All
: Applies only to any zones within the specified time period
→
Zone
: Applies for the selected zone in the specified time period
Heating and domestic hot water mode is switched off, existing ventilation operates at the lowest
ventilation level, frost protection is activated
→
Cooling for several days
Cooling mode is activated in the specified time period, cooling mode and desired temperature are
used from the
Cooling
function
→
Fixed value control, circuit 1
→
Heating
→
Mode:
→
Manual
Uninterrupted retention of the
Target flow temp., desired: °C
that the competent person set.
→
Time-contr.
→
Weekly planner