Product description 4
0020196687_03 flexoTHERM exclusive Installation and maintenance instructions
11
1
2
3
4
5
11
12
9
10
8
7
6
1
Electric back-up heater
2
Condenser
3
Heating pump
4
Electronic expansion
valve EVI (intermediate
circuit injection)
5
Heating circuit
filling/draining cock
6
Data plate
7
Carrying straps for
transport
8
Compressor
9
Electronic expansion
valve
10
Brine circuit
filling/draining cock
11
Brine circuit pump
12
Evaporator (not visible)
4.1.2
Rear view
1
2
4
3
5
6
7
1
Connection: From the
heat pump to the heat
source (cold brine, B)
2
Connection: From the
heat source to the heat
pump (hot brine, A)
3
Hot water return
4
Heating circuit dia-
phragm expansion ves-
sel connection
5
Heating return
6
Heating flow
7
Recessed handles and
grommet
4.2
Information on the data plate
The main data plate is attached behind the front casing on
the front cover of the refrigerant circuit.
Information on the data plate
Meaning
Rated voltage of the com-
pressor
Rated voltage of the pumps
and control
Back-up heater rated voltage
P max
Maximum rated power
P max
Max. rated power of the
compressor, pumps and
control
P max
Max. rated power of the
back-up heater
I max +
30 A
Maximum in-rush current
Refrigerant type, fill quantity,
permissible rated overpres-
sure
COP B0/W35 /W45 /W55
Coefficient of Performance
at a brine temperature of
X °C and a heating flow
temperature of X °C
B0/W35 /W45 /W55
Heating output at a brine
temperature of X °C and a
heating flow temperature of
XX °C
COP A2/W35, A7/W35, A7/W45,
A7/W55
Coefficient of Performance
at an air temperature of
X °C and a heating flow
temperature of XX °C
EER A35/W1835
Energy Efficiency Ratio at an
air temperature of XX °C and
a heating flow temperature
of XX °C
A2/W35, A7/W35, A7/W45,
A7/W55
Heat output at an air temper-
ature of X °C and a heating
flow temperature of XX °C
A35/W18
Cooling output at an air
temperature of X °C and a
heating flow temperature of
XX °C
COP W10/W35 /W45 /W55
Coefficient of Performance at
a ground-water temperature
of X °C and a heating flow
temperature of XX °C
W10/W35 /W45 /W55
Heat output at a ground-wa-
ter temperature of X °C and
a heating flow temperature
of XX °C
V
Mains voltage
Hz
Mains frequency
W
Power consumption
IP
Protection class
Barcode with serial number,
7th to 16th digits = product
article number