background image

3 Product description

6

Operating instructions ecoVIT exclusiv 0020258609_00

3

Control (accessory)

4

Main switch

5

+

button

6

button

7

Reset

button

8

Heating flow temperat-
ure rotary knob

9

Cylinder temperature
rotary knob

The display shows the current heating flow temperature, the
filling pressure of the heating installation, the operating mode
or certain additional information.

The

i

button is used to call up status information.

The control, which is available as an accessory, automatic-
ally controls the flow temperature depending on the outdoor
temperature.

The main switch is used to switch the product on and off.

The

+

button is used to display the cylinder temperature (if

the product is equipped with a cylinder temperature sensor).

The

button is used to display the filling pressure of the

heating installation.

The

Reset

button is used to reset the product in the case of

certain faults.

The heating flow temperature rotary knob is used to set the
heating flow temperature if no control is connected. If a con-
trol is connected, the heating flow temperature rotary knob
should be turned clockwise as far as it will go.

The cylinder temperature rotary knob is used to set the cyl-
inder temperature if a domestic hot water cylinder is connec-
ted.

If a control is connected, the rotary knob should be turned
clockwise as far as it will go. The control then determines the
cylinder temperature.

3.3.1

Digital Information and Analysis System
(DIA)

1

2

1

Display showing the
current heating flow
temperature, the filling
pressure in the heating
installation, or a status
or fault code

2

Plain text display

3.3.2

Displayed symbols

Symbol

Meaning

Explanation

Fault in the air/flue gas
route

Fault in the air/flue gas
route

Symbol

Meaning

Explanation

comDIALOG

The heating flow and do-
mestic hot water temper-
ature are specified via
the comDIALOG com-
munications system. The
product works at temper-
atures other than those
set at the rotary knob.
This operating mode can
only be terminated by:

comDIALOG

Changing the tem-
perature at the rotary
knobs by more than

±

5 K

This operating mode
cannot be terminated by:

Pressing the

Reset

button.

Switching the
product off and on
again

Heating mode

Symbol perman-
ently on: Product is
in heating mode op-
erating mode

Symbol flashing:
Burner anti-cycling
time is active

Hot water generation

Symbol permanently
visible: Charging
mode for the do-
mestic hot water
cylinder is enabled
by the control and
floor-standing boiler
control system

Symbol flashes:
Domestic hot water
cylinder is being
heated

Heating pump operating

Solenoid valve is actu-
ated

Gas supply to the burner
is open

Current energy demand

Display of the current
burner modulation rate
(bar graph display)

Fault during burner
operation

Burner is switched off

Burner operating cor-
rectly

Burner is switched on

Содержание ecoVIT exclusiv VKK 226/4-H

Страница 1: ...ting instructions ecoVIT exclusiv VKK 226 4 VKK 656 4 AT DE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www vaillan...

Страница 2: ...3 Setting the language 8 4 4 Setting the heating flow temperature 8 4 5 Setting the cylinder temperature 9 4 6 Switching off the functions 9 4 7 Status code meanings 10 5 Care and maintenance 10 5 1 C...

Страница 3: ...d understand the hazards involved Children must not play with the product Cleaning and user maintenance work must not be carried out by children unless they are supervised Any other use that is not sp...

Страница 4: ...caused by insufficient supply of combustion air Conditions Open flued operation Ensure that there is a sufficient supply of combustion air 1 3 8 Risk of corrosion damage due to unsuitable combustion a...

Страница 5: ...ct article number VKK 226 4 H 0010007508 VKK 226 4 L 0010007688 VKK 286 4 H 0010007512 VKK 286 4 L 0010007692 VKK 366 4 H 0010007516 VKK 366 4 L 0010007696 VKK 476 4 H 0010007520 VKK 476 4 L 001000770...

Страница 6: ...turned clockwise as far as it will go The control then determines the cylinder temperature 3 3 1 Digital Information and Analysis System DIA 1 2 1 Display showing the current heating flow temperature...

Страница 7: ...Adjustment and display levels The product has two adjustment and display levels The end user level contains information and setting options that you require as the end user The installer level is rese...

Страница 8: ...low temperature is automatically set by the control Note To ensure that the control can set temper atures up to the maximum heating flow temperature the rotary knob for the heating flow temperature sh...

Страница 9: ...C is required we recommend that you regularly use the anti legionella function via the control Position Meaning Temperature Fully left Minimum cylinder temperature frost protection 15 Centre Medium cy...

Страница 10: ...esults 5 3 Guaranteeing the correct filling pressure of the heating installation 5 3 1 Checking the system pressure 1 1 button Check the heating installation s filling pressure at regular intervals Br...

Страница 11: ...e discharge pipe and tun dish for faults and particularly for blockages You must not be able to see or feel any obstructions in the condensate discharge pipe and tundish If you notice a fault have it...

Страница 12: ...is connected to the power mains the product is switched on via the main switch and the gas stopcock is open You must use the control if you want to activate and deactivate the product in normal mode...

Страница 13: ...e Instead hand in the product to a collection centre for old electrical or electronic appliances If the product contains batteries that are marked with this symbol these batteries may contain substanc...

Страница 14: ...ted there is no heat demand The external control blocks heating mode S 34 Heating mode Frost pro tection The frost protection function for heating mode is activated B Troubleshooting Symptom Possible...

Страница 15: ...the heating flow temperature is not at the clockwise end stop when the control is connected 1 Check the setting of the rotary knob for the heating flow tem perature when the control is connected 2 Tu...

Страница 16: ...8 0 Telefax 021 91 18 2810 Auftragsannahme Vaillant Kundendienst 021 91 5767901 info vaillant de www vaillant de These instructions or parts thereof are protected by copyright and may be reproduced or...

Отзывы: