51
Installation and maintenance instructions ecoTEC 0020029173_01
10 Replacing
components
The tasks listed below in this section may be carried out
only by a heating engineer.
• Only use genuine spare parts for repairs.
• Make sure the parts are correctly fitted and that their
original position and alignment are retained.
10.1 Safety
instructions
d
Danger!
Each time components are replaced, comply
with the safety instructions below for your own
safety and to avoid damage to the boiler.
• Take the boiler out of operation.
e
Danger!
Risk of fatal electric shock through contact
with live connections!
Disconnect the boiler from the power mains by
de-energising the boiler using an isolating
device with a contact opening of at least 3 mm
(e.g. fuses or power switches).
• Close the gas isolation valve and the service valves in
the heating supply and return.
• Close the service valve in the cold water supply pipe.
• Empty the boiler if you want to replace water-bearing
components of the boiler.
• Make sure that water does not drip on live
components (e.g. the electronic box).
• Use only new seals and O-rings!
• After completing the work, perform a tightness check
and function check (see Chap. 6.4).
10.2 Replacing
the
burner
d
Danger!
Before replacing the component, observe the
safety information in Chap. 10.1.
• Dismount the compact thermal module as described in
Chap. 8.3.1.
1
Fig. 10.1 Replacing the burner
• Release the four screws (
1
) on the burner, and remove
the burner.
• Mount the new burner with a new seal. Make sure the
seal notch for the inspection glass fits into the notch
of the burner flange.
• Re-install the compact thermal module as described in
Chap. 8.3.4.
• After completing the work, perform a gas-tightness
check and function check (see Chap. 8.9)
10.3
Replacing the fan or gas valve
d
Danger!
Before replacing the component, observe the
safety information in Chap. 10.1.
• Remove the compact thermal module as described in
Chap. 8.3.1.
• Replace the defective components.
d
Danger!
Danger of personal injury and damage to
property from gas escapes!
The gas valve and fan must be returned to their
previous installation position. Use new seals
without exception!
• Re-install the complete "gas valve/fan" boiler in the
reverse sequence.
• After completing the work, perform a gas-tightness
check and function check (see Chap. 8.9)