0020253094_05 ecoTEC sustain Installation and maintenance instructions
49
D
Status codes
–
Overview
Note
Since the code table is used for various products, some codes may not be visible for the product in question.
Status code
Meaning
Displays in heating mode
S.00
Heating mode: No requirement
S.01
Heating mode: Fan prerun
S.02
Heating mode: Pump prerun
S.03
Heating mode: Burner ignition
S.04
Heating mode: Burner on
S.05
Heating mode: Pump/fan overrun
S.06
Heating mode: Fan overrun
S.07
Heating mode: Pump overrun
S.08
Heating mode: Temporary shutdown after heating procedure
Displays in domestic hot water mode
S.10
Domestic hot water mode: Requirement
S.11
Domestic hot water mode: Fan prerun
S.13
Domestic hot water mode: Burner ignition
S.14
DHW mode: Burner on
S.15
DHW mode: Pump/fan overrun
S.16
DHW mode: Fan overrun
S.17
DHW mode: Pump overrun
Display in comfort mode with warm start or domestic hot water mode with cylinder
S.20
Domestic hot water mode: Requirement
S.21
Domestic hot water mode: Fan prerun
S.22
Domestic hot water mode: Pump prerun
S.23
Domestic hot water mode: Burner ignition
S.24
DHW mode: Burner on
S.25
DHW mode: Pump/fan overrun
S.26
DHW mode: Fan overrun
S.27
DHW mode: Pump overrun
S.28
Domestic hot water mode: Temporary shutdown of the burner
Other displays
S.30
Room thermostat is blocking heating mode.
S.31
No heating demand: Summer mode, eBUS control, waiting period
S.32
Fan waiting time: Fan speed outside of the tolerance values
S.34
Frost protection active
S.39
Underfloor heating contact open
S.42
Accessory fault: Flue non-return flap closed or condensate pump fault
S.53
Product in waiting period/operating block function due to water deficiency (flow/return spread too large)
S.54
Waiting period: Water deficiency in the circuit (flow/return spread too large)
S.88
Product purging active
S.91
Maintenance: Operating display demo mode
S.96
Automatic test programme: Flow and return temperature sensors, heating and domestic hot water demand
blocked or product fault.
S.98
Automatic test programme: Return temperature sensor, heating and domestic hot water demand blocked.
S.108
Purging the combustion chamber, fan in operation
S.109
Product's standby mode activated