Appendix
0020258017_00 ecoTEC pure Operating instructions
17
Appendix
A Operator level
–
overview
Setting level
Values
Increment, select, explanation
Default set-
ting
Min.
Max.
Domestic hot water mode
(product with integrated hot water generation or connected
domestic hot water cylinder with temperature sensor)
Water temperature
Current value < 35 = OFF
OFF
35
℃
60
℃
Heating mode
Heating flow temperat-
ure
Current value < 10 = OFF
Underfloor heating = 35-50
Radiator = 35-80
Note
The temperature range above 75 °C
can only be set by a competent per-
son.
OFF
10
℃
80
℃
B Status codes
–
Overview
Note
Since the code table is used for various products, some codes may not be vis-
ible for the product in question.
Codes that are not listed here can be found in the installation instructions.
Status code
Meaning
Displays in heating mode
S.00
Heating mode: No requirement
S.02
Heating mode: Pump pre-run
S.03
Heating mode: Burner ignition
S.04
Heating mode: Burner on
S.06
Heating mode: Fan overrun
S.07
Heating mode: Pump overrun
S.08
Heating mode: Temporary shutdown after heating procedure
Displays in hot water handling mode
S.10
Hot water handling mode: Requirement
S.14
DHW mode: Burner on
Display in Comfort mode with warm start or hot water handling mode with cylinder
S.20
Hot water handling mode: Requirement
S.22
Hot water handling mode: Pump pre-run
S.24
DHW mode: Burner on
Other displays
S.31
No heating demand: Summer mode, eBUS controller, waiting period
S.34
Frost protection active