background image

1 Safety

4

Operating

 

instructions

 

ecoTEC

 

plus

 

0020239012_02

1.3 General safety

information

1.3.1 Installation by skilled

tradesmen only

The installation, inspection,
maintenance and repair of the
product, as well as the gas ratio
settings, must only be carried
out by a competent person.

1.3.2 Danger caused by

improper operation

Improper operation may present
a danger to you and others, and
cause material damage.

Carefully read the enclosed
instructions and all other ap-
plicable documents, particu-
larly the "Safety" section and
the warnings.

Only carry out the activities
for which instructions are
provided in these operating
instructions.

1.3.3 Risk of death from

escaping gas

What to do if you smell gas in
the building:

Avoid rooms that smell of
gas.

If possible, open doors and
windows fully and ensure
adequate ventilation.

Do not use naked flames (e.g.
lighters, matches).

Do not smoke.

Do

 

not

 

use

 

any

 

electrical

 

switches,

 

mains

 

plugs,

 

door-

bells,

 

telephones

 

or

 

other

 

communication

 

systems

 

in

 

the

 

building.

If

 

it

 

is

 

safe

 

to

 

do

 

so,

 

close

 

the

 

emergency

 

control

 

valve

 

or

 

the

 

main

 

isolator.

If

 

possible,

 

close

 

the

 

gas

 

isol-

ator

 

cock

 

on

 

the

 

product.

Warn

 

other

 

occupants

 

in

 

the

 

building

 

by

 

yelling

 

or

 

banging

 

on

 

doors

 

or

 

walls.

Leave

 

the

 

building

 

immedi-

ately

 

and

 

ensure

 

that

 

others

 

do

 

not

 

enter

 

the

 

building.

Notify

 

the

 

gas

 

supply

 

com-

pany

 

or

 

the

 Emergency 

Service Provider

+44

 

(0)

 

800

 

111999

 

by

 

tele-

phone

 

once

 

you

 

are

 

outside

 

of

 

the

 

building.

1.3.4 Risk of death due to a

blocked or leaking flue
gas pipe

What to do if you smell flue gas
in the property:

Open all accessible doors
and windows fully to provide
ventilation.

Switch off the product.

Inform a competent person.

Содержание ecoTEC plus VU 6/6-5 OVZ Series

Страница 1: ...ting instructions ecoTEC plus VU 6 6 5 OVZ H GB GB IE Operating instructions Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vailla...

Страница 2: ...2 Opening and closing the front flap 11 4 3 Switching on the product 11 4 4 Setting the language 11 4 5 Setting the hot water temperature 11 4 6 Setting the heating flow temperature 11 4 7 Switching o...

Страница 3: ...al heating installations and for hot water generation Intended use includes the fol lowing observance of the operating instructions included for the product and any other system components compliance...

Страница 4: ...rooms that smell of gas If possible open doors and windows fully and ensure adequate ventilation Do not use naked flames e g lighters matches Do not smoke Do not use any electrical switches mains plug...

Страница 5: ...not make any changes The product itself to the gas air water and electricity supplies to the entire flue gas install ation to the entire condensate drain system to the expansion relief valve to the d...

Страница 6: ...t all rooms are sufficiently heated If you cannot ensure the op eration have a competent person drain the heating in stallation 1 3 11 Risk of injury and material damage due to maintenance and repairs...

Страница 7: ...formation on the identification plate The identification plate is mounted on the underside of the product in the factory The identification plate keeps record of the country in which the product is to...

Страница 8: ...ties on both manufacturers and installers The purpose is to ensure that customers are provided with the correct equipment for their needs that it is installed commissioned and serviced in accordance w...

Страница 9: ...t burner modulation rate Sym bol Meaning Explanation Heating mode active Permanently on Heating mode heat requirement Flashing Burner on in heating mode Maintenance re quired Information on the mainte...

Страница 10: ...switch back to the basic display by Pressing to exit the selection levels Not pressing any button for longer than 15 minutes If there is an error message present the basic displays switches to the err...

Страница 11: ...st Le gionella Set the hot water temperature to a maximum of 50 C 45 DHW temperature Back 1 Press The set hot water temperature flashes in the display Conditions No controller connected Change the hot...

Страница 12: ...and that all rooms are sufficiently heated even when you are away Note To keep the frost protection devices active you should switch your product on and off using the controller if one is provided If...

Страница 13: ...in pipe work and tundish If you notice a fault have it rectified by a competent person 7 4 Reading maintenance messages If the symbol is shown in the display the product requires maintenance work The...

Страница 14: ...approved at the time by the Health and Safety Executive one year after install ation The cost of this annual service is not included in the guarantee Registering with us Registration is simple Just co...

Страница 15: ...ng is dis connected Check the fuse in the building The product switches on automat ically when the power is restored The product is switched off Switch on the product The heating flow temperature is s...

Страница 16: ...Operating instructions ecoTEC plus 0020239012_02 Fault Cause Measure Heating does not start The external controller is not set cor rectly Set the external controller cor rectly Controller operating in...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...e DE56 1JT Telephone 0330 100 3461 info vaillant co uk www vaillant co uk These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer...

Отзывы: