Instructions for use ecoTEC plus / 0020020829_03

6

4 Operation

4.1 

Overview of controls on ecoTEC plus

1

 8

7

6

5

4

2

3

Fig. 4.1 ecoTEC plus controls

For access to the controls open the front flap by pulling 
at the centre of the case strip.

1  Display indicating the current heating flow temperature, the 

operating mode or additional information.

2  The “i” information button.
3  Built in control/timer (if fitted).
4  “+” button for moving forward in the display.
5  “-” button for moving back in the display.
6 “Reset” 

button.

7  Maximum radiator temperature control.
8  Optional maximum hot water temperature control available 

only when additional optional accessories are fitted (VR 65, 
VRT 360, VRC 400).

Advanced multifunctional display system

1

Fig. 4.2  Display on ecoTEC plus

The ecoTEC plus appliance is fitted with a digital infor-
mation and analysis system. This system provides infor-
mation on the operating status of your appliance.During 
normal operation, the display (1) shows the current 
heating flow temperature (in this example 45 °C). In the 
event of a fault, an error code appears instead of the 
temperature. The display also gives the following infor-
mation:

1

Indication of the current heating flow temperature or 
display of a status or error code

Fan speed malfunction.

Fan speed malfunction.

 As long as this symbol appears in the display, a heating 
flow temperature is set by the vrnetDIALOG accessory, 
which means the appliance uses temperatures other 
than those set using the controls (7) and (8).
This condition can only be ended:
- using vrnetDIALOG or
-  by a change in temperature at controllers (7) or (8) 

of more than = 

± 

K.

This condition cannot be ended:
- with the “Reset” button (6) or
- by turning the appliance off or on.

Heating mode active.
Illuminated: Heating mode.
Flashing: Anti cycling mode active.

Hot water supply active.
Illuminated: Heating of an indirect hot water cylinder 
turned on.
Flashing: Heating demand from the hot water cylinder, 
burner on if optional accessories are fitted.

  External pump is running.

Gas valve is activated.

 Flame with cross:
Boiler is at lock out and will display fault code.

 Flame without cross:
Normal burner operation.

4.2 

Initial checks before turning on

4.2.1 

Opening the gas service valve

•  Ensure the gas service valve is open.
•  Ensure the electrical supply to the boiler is turned on.

off

on

Fig. 4.3  Opening the gas service valve

4 Operation

Содержание ecoTEC plus SERIES

Страница 1: ...Instructions for use ecoTEC plus Wall hung open vent condensing boiler GB For the owner...

Страница 2: ...a room or outside temperature controller 7 4 6 Pump exercise 8 4 7 Status displays 8 4 8 Troubleshooting 8 4 8 1 Ignition problems 8 4 8 2 Flue problems 8 4 9 Turning off the boiler 9 4 10 Frost prot...

Страница 3: ...r installer or Vaillant Technical Department 1 1 2 Retention of the documents Please store this literature and all related documents so that they are available whenever they are required If you move p...

Страница 4: ...or other parts of the system Never attempt to perform mainte nance or repairs yourself Do not damage or remove seals on components Only authorised engineers or our customer service may remove sealed c...

Страница 5: ...tions Nevertheless there is a risk of injury or death to the user or others and damage to the appliance or other property in the event of misuse or use for which the appli ance is not intended This ap...

Страница 6: ...of the temperature The display also gives the following infor mation 1 Indication of the current heating flow temperature or display of a status or error code Fan speed malfunction Fan speed malfuncti...

Страница 7: ...stic hot water temperature can be adjusted using the hot water temperature control 3 Turn the control clockwise to increase the tempera ture and anti clockwise to decrease the temperature This corresp...

Страница 8: ...or example S 4 for burner operation The table below explains the most important status codes In switching phases for example on starting up again after the flame was extinguished the status message S...

Страница 9: ...e when you are on holiday you should also turn off the gas supply and the electrical supply 4 10 Frost protection The frost protection feature only protects the boiler Any other parts of the system li...

Страница 10: ......

Страница 11: ......

Страница 12: ...0020020829_03_GB 03 2008...

Отзывы: