background image

Safety 1

0020193967_01 ecoTEC exclusive Operating instructions

3

1

Safety

1.1

Action-related warnings

Classification of action-related warnings

The action-related warnings are classified in
accordance with the severity of the possible
danger using the following warning signs and
signal words:

Warning symbols and signal words

Danger!

Imminent danger to life or risk of
severe personal injury

Danger!

Risk of death from electric shock

Warning.

Risk of minor personal injury

Caution.

Risk of material or environmental
damage

1.2

Intended use

There is a risk of injury or death to the user or
others, or of damage to the product and other
property in the event of improper use or use
for which it is not intended.
The product is intended as a heat generator
for closed heating installations and for hot
water generation.
Intended use includes the following:

observance of the operating instructions
included for the product and any other
system components

compliance with all inspection and main-
tenance conditions listed in the instruc-
tions.

This product can be used by children aged
from 8 years and above and persons with
reduced physical, sensory or mental capabil-
ities or lack of experience and knowledge if
they have been given supervision or instruc-
tion concerning use of the product in a safe
way and understand the hazards involved.
Children must not play with the product.
Cleaning and user maintenance work must
not be carried out by children unless they are
supervised.
Any other use that is not specified in these
instructions, or use beyond that specified in

this document shall be considered improper
use. Any direct commercial or industrial use
is also deemed to be improper.

Caution.

Improper use of any kind is prohibited.

1.3

General safety information

1.3.1 Installation by competent persons

only

The installation, inspection, maintenance
and repair of the product, as well as the gas
ratio settings, must only be carried out by a
competent person.

1.3.2 Danger caused by improper

operation

Improper operation may present a danger to
you and others, and cause material damage.

Carefully read the enclosed instructions
and all other applicable documents, par-
ticularly the "Safety" section and the warn-
ings.

Only carry out the activities for which in-
structions are provided in these operating
instructions.

1.3.3 Risk of death from escaping gas

What to do if you smell gas in the building:

Avoid rooms that smell of gas.

If possible, open doors and windows fully
and ensure adequate ventilation.

Do not use naked flames (e.g. lighters,
matches).

Do not smoke.

Do not use any electrical switches, mains
plugs, doorbells, telephones or other com-
munication systems in the building.

If it is safe to do so, close the emergency
control valve or the main isolator.

If possible, close the gas isolator cock on
the product.

Warn other occupants in the building by
yelling or banging on doors or walls.

Leave the building immediately and ensure
that others do not enter the building.

Notify the gas supply company or the Na-
tional Grid +44 (0) 800 111999 by tele-
phone once you are outside of the build-
ing.

Содержание ecoTEC exclusive 627

Страница 1: ...TEC exclusive 627 VU 256 5 7 H GB 835 VUW 356 5 7 H GB 843 VUW 436 5 7 H GB GB IE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info v...

Страница 2: ...e product 8 4 9 Setting the language 8 4 10 Setting the domestic hot water temperature 8 4 11 Switching Comfort mode on and off 8 4 12 Setting the heating flow temperature 8 4 13 Switching Green iQ mo...

Страница 3: ...children unless they are supervised Any other use that is not specified in these instructions or use beyond that specified in this document shall be considered improper use Any direct commercial or in...

Страница 4: ...y of the product 1 3 7 Risk of poisoning caused by insufficient combustion air supply Conditions Open flued operation Ensure that there is a sufficient combus tion air supply 1 3 8 Risk of corrosion d...

Страница 5: ...exclusive 0010017065 47 044 67 3 Product description 3 1 Product design 1 2 3 1 Control elements 2 Plate with serial number on the rear 3 Front flap 3 2 Control elements 50 5 4 3 2 1 1 On off button 2...

Страница 6: ...eneration equipment ecoTEC exclusive Product description Information on the identification plate Meaning 2H G20 20 mbar 2 0 kPa Gas group and gas connection pressure as set at the factory ww yyyy Date...

Страница 7: ...ls Not pressing any button for longer than 15 minutes If there is an error message present the basic displays switches to the error message 4 3 Menu display Xxxx Xxxxxxxxxxx Xxxx Xxxxxxx Xxxxxxxxxx xx...

Страница 8: ...Comfort mode on and off Applicability Product with integrated hot water generation Note Comfort mode immediately supplies hot water at the required temperature without you having to wait for the wate...

Страница 9: ...e installation with suf ficient heating water the display automatically disappears after 20 seconds 4 14 2 Filling the heating installation Caution Risk of material damage due to heating water that is...

Страница 10: ...nsure that the heating installation remains in operation and that all rooms are sufficiently heated even when you are away Note To keep the frost protection devices active you should switch your produ...

Страница 11: ...disposal of the packaging If the product is identified with this symbol In this case do not dispose of the product with the household waste Instead hand in the product to a collection centre for waste...

Страница 12: ...op valve The power supply in the building is disconnected Check the fuse in the building The product switches on automatically when the power is restored The product is switched off Switch on the prod...

Страница 13: ...ng mode Pump overrun S 08 Heating remaining anti cycling time xx mins S 09 Heating mode Measuring programme Domestic hot water mode products with integrated domestic hot water generation S 10 Domestic...

Страница 14: ...Appendix 14 Operating instructions ecoTEC exclusive 0020193967_01 Status code Meaning S 58 Modulation limitation due to noise wind S 76 System pressure too low Top up water...

Страница 15: ......

Страница 16: ...e DE56 1JT Telephone 0330 100 3461 info vaillant co uk www vaillant co uk These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer...