Installation and maintenance manual ecoLEVEL 

4 Mounting

4.1 

Scope of delivery

Description

Dimensions

Quantity

Condensate pump

180 x 160 x 100 mm

1

Wall plugs

5 mm

2

Screws

4 x 35 mm

2

Feed hose

Ø 24 mm x 1.15 m

1

Discharge hose

Ø 10 mm x 6 m

1

Wall bracket

-

1

Wall bracket for drain hose -

6

Operating, Installation, and 
maintenance manuals

-

1

Table 4.1 Scope of delivery

The following tools are required for installation:
- Drill
-  Drill bit (5 mm)
-  Slot head screwdriver
- Water-level
- Cutting blade
-  Tools for making electrical connections

4.2 

Selecting the installation site

The ecoLEVEL condensate pump should be installed in 
the room where the boiler is located. 
The ambient room temperature must be between 5 °C 
and 60 °C.
The pump should be fixed to a wall that is suitable for 
installation using the provided mounting hardware. If a 
suitable wall is not available, a suitable mounting surface 
must be prepared. 
The ecoLEVEL condensate pump should not be used as 
a storage shelf.

4.3 

Dimensions and clearances

100 mm

90 mm

165 mm

115 mm

150 mm

175 mm

min. 2

00 mm

min. 5 mm

min. 5 mm

min. 2

00 mm

min. 5 mm

min. 5 mm

Fig. 4.1 Dimensions and installation spaces

4.4 

Installing the wall bracket

•  Slide the pre-assembled wall bracket downward and 

out of the condensate pump housing.  

•  Install the wall bracket (as shown in Fig. 4.2) in a suita-

ble position below the point where the condensate 
drains out of the boiler.
The wall bracket must be installed in a level position! 
Use a spirit-level!

•  From above, slide the condensate pump straight down 

along the guiding edges of the wall bracket.
A small hook at the lowest position catches the pump 
and secures it in the wall bracket. 

 Note!

The condensate pump can be fastened to the 
wall bracket (as shown in Fig. 4.1) either on its 
narrow or on its wide side.

4 Mounting

Содержание ecoLEVEL

Страница 1: ...ecoLEVEL GB DE AT CH BE NL IT PL ...

Страница 2: ......

Страница 3: ... 2 2 Safety instructions and regulations 2 3 Instructions on operation 3 3 1 Vaillant warranty 3 3 2 Intended use 3 3 3 Care 3 3 4 Recycling and disposal 3 4 Operation and maintenance 3 4 1 General information 3 4 2 Display of operating status 3 4 3 Maintenance 3 For the owner Operating manual ecoLEVEL Condensate pump ...

Страница 4: ...ymbol for a necessary task 2 Safety instructions and regulations In general modifications to the ecoLEVEL condensate pump are forbidden For modifications to the environ ment you must refer to a suitably qualified heating engineer who is responsible for it Caution Risk of damage due to improper modifications Under no circumstances should you ever attempt to make modifications to the pump or other p...

Страница 5: ...rials Appliance Neither the pump or any of its accessories belong in the household waste Make sure the old appliance and any related accessories are disposed of properly Packaging Please leave the disposal of the transport packaging to the technician who installed the appliance 4 Operation and maintenance 4 1 General information The ecoLEVEL condensate pump is used for the extrac tion of condensat...

Страница 6: ......

Страница 7: ...nstallation site 4 4 3 Dimensions and clearances 4 4 4 Installing the wall bracket 4 5 Installation 5 5 1 Connecting the feed hose 5 5 2 Connecting and laying the discharge hose 6 5 3 Connecting to the boiler 6 6 Electrical connection 7 6 1 General information 7 6 2 Connecting the 230 V mains voltage 7 6 3 Connecting the overflow safety switch 7 7 Start up 10 7 1 Display of operating status 10 8 M...

Страница 8: ...ating engineer Standards and regulations IEC 60364 7 712 Electrical installations of buildings Part 7 712 EMV test procedures in accordance with EN50081 1 1992 EN50082 1 1997 Emission interference EN 55014 1 1993 Interference resistance EN 55014 2 1997 Engineering rules The installation must correspond to the site conditions to local regulations and last but not least to the engi neering rules Acc...

Страница 9: ...Caution Risk of damage due to improper modifications Under no circumstances should you ever attempt to make modifications to the pump or other parts of the system 3 Information on installation and operation 3 1 Vaillant warranty We only grant a Vaillant manufacturers warranty if a suitably qualified engineer has installed the system in accordance with Vaillant instructions The system owner will be...

Страница 10: ...he provided mounting hardware If a suitable wall is not available a suitable mounting surface must be prepared The ecoLEVEL condensate pump should not be used as a storage shelf 4 3 Dimensions and clearances 100 mm 90 mm 165 mm 115 mm 150 mm 175 mm min 200 mm min 5 mm min 5 mm min 200 mm min 5 mm min 5 mm Fig 4 1 Dimensions and installation spaces 4 4 Installing the wall bracket Slide the pre asse...

Страница 11: ...or kinks in the hose to ensure that condensate can flow unob structed into the pump Determine the required length of the hose When shortening the hose allow a min of 10 mm extra length for the insertion depth of the hose in the pump s cover Rotate the non return valve 1 one quarter turn to the left anticlockwise in order to open the cover 2 on the pump This unlocks both the cover and the return va...

Страница 12: ...rainage point can be compensated for and so that a slope in the hose can be created between the deflection point and the drain age point when the hose is laid Caution Observe the pump s maximum delivery height of 4 m Then lay the discharge hose with a constant slope down to the drainage point Position the discharge hose with a U shape at the highest point to prevent backflow max 4 0 m ca 3 Fig 5 2...

Страница 13: ...Connection cable fit a 3 pin plug if required 2 Connection cable for the overflow safety switch 6 2 Connecting the 230 V mains voltage There are two options for connecting the 230 V mains voltage You can connect the cable 1 to the 230 V mains via the mains connection on the boiler or You can install a mains plug on the cable 1 and con nect the pump with a mains socket the plug is not included in t...

Страница 14: ...ectrical box Remove the cable bridge from the blue slot Anl Therm on the circuit board Plug the blue Pro E plug on the end of the ecoLEVEL condensate cable into this slot 9 8 7 5 4 3 N L N L Pumpe 2 Pumpe Anl Therm L N 24V I 230V RT 24V 230V RT 230V X 10 X 7 X 8 X 2 13 1 1 1 1 Codierwiderstand 1 2 Fig 6 2 Connecting the overflow safety switch connection type A 6 Electrical connection ...

Страница 15: ... B Connection type C When installed as shown here the condensate pump will isolate the boiler in the event that the pump fails or in the event that the overflow safety switch in the pump is activated e g if it is blocked This will prevent the boiler from continuing to produce condensate and prevent the risk of flooding Connect the overflow safety switch to the boiler in the following manner Using ...

Страница 16: ...d Note Maintenance on the pump can be scheduled to coincide with the maintenance intervals for the boiler The pump should be serviced at least once a year 9 Troubleshooting 9 1 Problems The ecoLEVEL condensate pump can rectify temporary faults during normal operation by itself The red LED sig nals the following operating conditions Green LED Red LED Meaning Flashes Lights up The maximum water leve...

Страница 17: ...iance for wall mounted installation Nominal capacity l 0 5 Mains voltage V 230 Max current consumption A 1 Frequency Hz 50 Max power rating W 22 Max pump head m 4 Volume flow l h 150 Dimensions Height mm 160 Width mm 180 Depth mm 100 Weight when filled with water kg 1 8 Feed hose max outside diameter mm 24 Discharge hose min inside diameter mm 10 Water infeed temperature C 1 60 Ambient temperature...

Страница 18: ......

Страница 19: ......

Страница 20: ...0020017507_00 GB DE AT CH BE NL IT PL 12 2005 ...

Отзывы: