4 Assembly
8
Installation and maintenance instructions ecoFIT pure 0020230533_01
Quantity
Description
1
Gas pipe
1
Expansion relief valve discharge pipe
1
Installation template
1
Enclosed documentation
4.4
Dimensions
96
121
34
123
185
390
123
170
702
150
1
2
3
5
4
1
Heating flow
2
Gas connection
3
Heating return
4
Connection on the back
of the air/flue pipe
5
Connection on the top
of the air/flue pipe
4.5
Minimum clearances
C
C
A
B
D
Minimum clearance
A
150 mm (upper air/flue gas connection)
20 mm (air/flue gas connection on the rear)
B
150 mm
C
5 mm
(70 mm if the side panels ought to be removed)
D
600 mm
It is not necessary to maintain a clearance between the
product and components made of combustible materials that
go beyond the minimum clearances.
4.6
Clearance from combustible components
It is not necessary to maintain a clearance between the
product and components made of combustible materials that
go beyond the minimum clearances (
→
Page 8).
4.7
Using the installation template
▶
Use the installation template to ascertain the locations at
which you need to drill holes and make breakthroughs.
4.8
Wall-mounting the product
Note
If you are using the rear air/flue gas connection,
install the air/flue pipe before you wall-mount the
product.
1.
Check whether the wall has sufficient load-bearing ca-
pacity to bear the operational weight of the product.