Assembly 4
0020230531_01 ecoFIT pure Installation and maintenance instructions
9
Quantity
Description
2
Connection pipe (heating flow and return)
1
Cold water connection pipe
1
Hot water connection pipe
1
Gas pipe
1
Expansion relief valve discharge pipe
1
Installation template
1
Enclosed documentation
4.4
Dimensions
96
121
34
123
185
390
123
58 58
170
702
150
1
2
3
4
5
7
6
1
Heating flow
2
Hot water connection
3
Gas connection
4
Cold water connection
5
Heating return
6
Connection on the back
of the air/flue pipe
7
Connection on the top
of the air/flue pipe
4.5
Minimum clearances
C
C
A
B
D
Minimum clearance
A
150 mm (upper air/flue gas connection)
20 mm (air/flue gas connection on the rear)
B
150 mm
C
5 mm
(70 mm if the side panels ought to be removed)
D
600 mm
It is not necessary to maintain a clearance between the
product and components made of combustible materials that
go beyond the minimum clearances.
4.6
Clearance from combustible components
It is not necessary to maintain a clearance between the
product and components made of combustible materials that
go beyond the minimum clearances (
→
Page 9).
4.7
Using the installation template
▶
Use the installation template to ascertain the locations at
which you need to drill holes and make breakthroughs.
4.8
Wall-mounting the product
Note
If you are using the rear air/flue gas connection,
install the air/flue pipe before you wall-mount the
product.