6 Operation
14
Installation and maintenance instructions ecoFIT pure 0020230531_01
5.5.6
Connecting controllers to the electronic
system
X2
X22
X41
– +
24V=
RT
BUS
Burner
off
X106
BUS
24 V
BUS
RT
B.of
f
B
ur
ner
of
f
R
T
24V
=
-
+
B
U
S
1
4
3
2
1
Safety thermostat for
floor-standing heating
2
24 V controller
3
eBUS controller or radio
receiver unit
4
Outside temperature
sensor, wired
1.
Open the electronics box. (
→
Page 13)
2.
Carry out the wiring. (
→
Page 13)
3.
Connect the individual components depending on the
type of installation.
Conditions
: If installing a multi-circuit controller.
▶
Change the pump's operating mode
d.18
from Eco (in-
termittently operating pump) to Comfort (continuously
operating pump).
Conditions
: When connecting a controller (230 V).
≤ 30 mm
N
L
X1
230V~
RT
▶
Connect the controller to the main plug.
▶
Remove the bridge from the plug
24V=RT
.
Conditions
: 230 V 3-wire connection
▶
Ensure that the controller is designed for a maximum
rated current of 7 A.
▶
Connect the controller to the main plug X1.
–
Terminal assignment: L
‑
line, N
‑
neutral conductor,
‑
earth
▶
Draw the operator's attention to the fact that the follow-
ing features are present with this type of installation.
◁
The frost protection function is deactivated. If the
product is installed in a room where there is a risk
of frost and it has not been protected by a room ther-
mostat, install an additional frost protection thermo-
stat.
◁
The pump programmes are not active.
◁
If the product is switched off, the display is switched
off.
◁
Each time the unit is started, the fan runs for
20 seconds.
◁
Residual heat in the heating return may result in the
product blocking the burner for 10 minutes.
4.
Close the electronics box.
6
Operation
6.1
Operating concept
The operating concept and the display and setting facilities
of the operator level are described in the operating instruc-
tions.
An overview of the display and setting options in the installer
level can be found in the section "Overview of the installer
level". (
→
Page 14)
6.2
Installer level overview
S.31
Code
D.---
PF
P.--
D F
--/--