1.3 General safety

information

1.3.1 Installation by

competent persons only

The installation, inspection,
maintenance and repair of the
product, as well as the gas ratio
settings, must only be carried
out by a competent person.

1.3.2 Danger caused by

improper operation

Improper operation may present
a danger to you and others, and
cause material damage.

Carefully read the enclosed
instructions and all other ap-
plicable documents, particu-
larly the "Safety" section and
the warnings.

Only carry out the activities
for which instructions are
provided in these operating
instructions.

1.3.3 Risk of death from

escaping gas

What to do if you smell gas in
the building:

Avoid rooms that smell of
gas.

If possible, open doors and
windows fully and ensure
adequate ventilation.

Do not use naked flames (e.g.
lighters, matches).

Do not smoke.

Do

 

not

 

use

 

any

 

electrical

 

switches,

 

mains

 

plugs,

 

door-

bells,

 

telephones

 

or

 

other

 

communication

 

systems

 

in

 

the

 

building.

If

 

it

 

is

 

safe

 

to

 

do

 

so,

 

close

 

the

 

emergency

 

control

 

valve

 

or

 

the

 

main

 

isolator.

If

 

possible,

 

close

 

the

 

gas

 

isol-

ator

 

cock

 

on

 

the

 

product.

Warn

 

other

 

occupants

 

in

 

the

 

building

 

by

 

yelling

 

or

 

banging

 

on

 

doors

 

or

 

walls.

Leave

 

the

 

building

 

immedi-

ately

 

and

 

ensure

 

that

 

others

 

do

 

not

 

enter

 

the

 

building.

Notify

 

the

 

gas

 

supply

 

com-

pany

 

or

 

the

 Emergency 

Service Provider

+44

 

(0)

 

800

 

111999

 

by

 

tele-

phone

 

once

 

you

 

are

 

outside

 

of

 

the

 

building.

1.3.4 Risk of death due to a

blocked or leaking flue
gas pipe

What to do if you smell flue gas
in the property:

Open all accessible doors
and windows fully to provide
ventilation.

Switch off the product.

Inform a competent person.

Содержание ecoFIT pure 612

Страница 1: ...Operating instructions ecoFIT pure 612 630 GB IE Operating instructions Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de...

Страница 2: ...tching on the product 11 4 8 Setting the heating flow temperature 11 4 9 Setting the hot water temperature 11 4 10 Switching off the product s functions 11 4 11 Guaranteeing the correct filling pressu...

Страница 3: ...t ing installations and for hot wa ter generation Intended use includes the fol lowing observance of the operating instructions included for the product and any other system components compliance with...

Страница 4: ...rooms that smell of gas If possible open doors and windows fully and ensure adequate ventilation Do not use naked flames e g lighters matches Do not smoke Do not use any electrical switches mains plug...

Страница 5: ...the expansion relief valve to the drain pipework to constructional condi tions that may affect the operational reliability of the product 1 3 7 Risk of corrosion damage due to unsuitable combustion a...

Страница 6: ...ial damage due to maintenance and repairs carried out incorrectly or not carried out at all Never attempt to carry out maintenance work or repairs on your product yourself Faults and damage should be...

Страница 7: ...Number VU 126 6 3 H GB 0010020395 41 694 03 VU 156 6 3 H GB 0010020396 41 694 04 VU 186 6 3 H GB 0010020397 41 694 05 VU 256 6 3 H GB 0010020398 41 694 06 VU 306 6 3 H GB 0010020399 41 694 07 3 Produ...

Страница 8: ...d off Sym bol Meaning Explanation Burner anti cyc ling time is active To avoid the need for frequent switching on and off increases the product s working life F XX Fault in the product Fault in the pr...

Страница 9: ...the applicable directives as stated on the iden tification plate The declaration of conformity can be viewed at the manufacturer s site 3 7 Benchmark Vaillant is a licensed member of the Benchmark Sch...

Страница 10: ...that are available depend on whether a controller is connected to the product You can switch back to the basic display by Pressing to exit the selection levels Not pressing any button for longer than...

Страница 11: ...controller Controller oper ating instructions 4 9 Setting the hot water temperature Warning Risk of being scalded by hot water To protect against Legionella the hot water can be heated up to above 60...

Страница 12: ...m filling pressures appear in the display 2 Check the filling pressure in the display 1 2 System pressure 0 10 0 20 MPa 1 00 2 00 bar The filling pressure is in the intended pressure range 2 2 Filling...

Страница 13: ...r to approx 30 C on both the heating side and the hot water side if available 4 12 2 Draining the heating installation When the unit is switched off for an exten ded period frost protection can be gua...

Страница 14: ...ipework and tundish The condensate drain pipework and tun dish must always be penetrable Regularly check the condensate drain pipework and tundish for faults and particularly for blockages You must no...

Страница 15: ...mbol these bat teries may contain substances that are hazardous to human health and the envir onment In this case dispose of the batteries at a collection point for batteries 9 Guarantee and customer...

Страница 16: ...and Hot water requirement S 22 DHW mode Pump pre run DHW mode Pump pre run S 24 DHW mode Burner on DHW mode Burner on Others S 31 No heat demand Summer mode Summer mode active S 34 Heating mode Frost...

Страница 17: ...ion Filling the heating installation section There is air in the heating installation Have your competent person purge the heating installation After three unsuccessful attempts to ignite the flame th...

Страница 18: ......

Страница 19: ......

Страница 20: ...e DE56 1JT Telephone 0330 100 3461 info vaillant co uk www vaillant co uk These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer...

Отзывы: