4 On-roof fitting and installation
14
Installation manual auroTHERM exclusive 0020077994_03
Conditions
: Collector rows: 3
A
B
B
A
▶
Use the following table to put together the components for installation.
Number of VTK 1140/2 collectors per row
1
2
3
4
5
6
7
Components
Required sets
VTK installation set (basic set)
3
1
VTK installation set (extension set)
−
3
6
9
12
15
18
Roof bracket set type P (pantile)
A
1
2
2
2
3
2
4
2
5
2
6
2
7
2
Roof bracket set type S (slate)
Roof bracket set type S, flat (slate)
Roof bracket set type P (pantile)
B
2
2
4
2
6
2
8
2
10
2
12
2
14
2
Roof bracket set type S (slate)
Roof bracket set type S, flat (slate)
Rail set (2), VTK 1140/2
3
6
9
12
15
18
21
1
1 set per row; the collectors are connected together using the extension set
–
if the rows are also connected together so that
they are flat-sealed.
2
Valid up to 700 m above sea level