Product description 3

0020290841_00 aroSTOR Operating instructions

9

3.3 Displayed symbols

Sym-
bol

Meaning

Compressor in operation

Fan in operation

Defrosting function active

Electric back-up heater in operation

Domestic hot water demand

ECO mode active

Frost protection mode active

Holiday mode active

Photovoltaic mode active

Display locked

Comfort mode active

Programming mode active

Additional boiler operating

3.4 Type designation and serial

number

1

The type designation and serial number
are on the data plate

(1)

.

3.5 Information on the data plate

The data plate is mounted on the right-
hand side of the product at the factory.

Information on the
data plate

Meaning

aroSTOR VWL

Type designation

BM

Cylinder type

200 / 270

Cylinder volume

/5

Unit version

Information on the
data plate

Meaning

COP

Coefficient of per-
formance

heating

230 V (single-phase)
~ 50 Hz

Voltage and fre-
quency of the
product's power
supply

P max

Max. power con-
sumption

I max

Max amperage of the
power supply circuit

IP...

IP rating/protection
class
Total weight of the
empty product
Nominal capacity of
the cylinder
Max. pressure in the
domestic hot water
circuit
Max. temperature
in the domestic hot
water circuit

P

The refrigeration cir-
cuit
Refrigerant type, fill
quantity, permissible
rated excess pres-
sure
Nominal heat output
of the refrigeration
circuit
Max. air flow in the
heat pump

P

Nominal heat output
of the electric back-
up heater

0.8 m

²

Circulation circuit

Barcode with serial
number,
The 7th to 16th digits
of the serial number
form the article num-
ber
Disposal of the pack-
aging

Содержание aroSTOR VWL BM 200/5

Страница 1: ...perating instructions aroSTOR VWL BM 200 5 VWL BM 270 5 KOsq Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 492191 18 0 Fax 492191 18 2810 info vaillant de www vaillant d...

Страница 2: ...3 Product description 8 3 1 Product design 8 3 2 Overview of the control elements 8 3 3 Displayed symbols 9 3 4 Type designation and serial number 9 3 5 Information on the data plate 9 3 6 CE marking...

Страница 3: ...ndix 16 A Troubleshooting 16 B Optimising energy consumption 17 B 1 Using a low tariff and a control cable connection 17 B 2 Using a low tariff without a control cable connection 18 B 3 Operating with...

Страница 4: ...ter generation Intended use includes the fol lowing observance of the operating instructions included for the product and any other install ation components compliance with all inspection and maintena...

Страница 5: ...g lighters matches Do not smoke Do not use any electrical switches mains plugs door bells telephones or other communication systems in the building Leave the building immedi ately and ensure that oth...

Страница 6: ...igerant circuit as a result of leaks Avoid skin or eye contact with the refrigerant In the event of skin or eye contact with the refrigerant seek medical advice 1 9 Risk of injury and material damage...

Страница 7: ...rooms are sufficiently heated You must observe the frost protection instructions 1 13 Avoid environmental damage caused by escaping refrigerant The product contains R 290 refrigerant The refrigerant...

Страница 8: ...number aroSTOR VWL BM 200 5 0010026818 aroSTOR VWL BM 270 5 0010026819 3 Product description The product operates at air temperatures between 7 C and 35 C Outside of this temperature range domestic ho...

Страница 9: ...VWL Type designation BM Cylinder type 200 270 Cylinder volume 5 Unit version Information on the data plate Meaning COP Coefficient of per formance heating 230 V single phase 50 Hz Voltage and fre quen...

Страница 10: ...hat the plugs 1 have been removed from the condensate discharge con nection 2 Ensure that the stopcock upstream of the safety assembly at the cold water inlet is open 3 Before switching on the power s...

Страница 11: ...roduct does not automatically switch between summer and winter time You must implement this con version manually Press the button to set the time Press the rotary knob to confirm Turn the rotary knob...

Страница 12: ...s energy consumption kWh by programming the operating hours Consider the following points when creating such a programme Electricity tariff tiers low high tariff peri ods Temperature of the drawn in a...

Страница 13: ...ys 1 day 24 hour time period the mode will be activated This mode temporarily suspends the set time programming The mode ends automatically once the set number of days has expired Throughout the holid...

Страница 14: ...atures below 60 C without consulting the competent person first Contact your competent person in order to have them activate or deactivate the anti legionella function or to find out more information...

Страница 15: ...on who installed your product is responsible for the dis posal of the packaging If the product is labelled with this mark In this case do not dispose of the product with the household waste Instead ha...

Страница 16: ...energy sources im mersion heater If the air inlet temperature is once again between 7 C or and 35 C the heat pump restarts Time programming conflicts with the high tariff load relief Check the time pr...

Страница 17: ...tion B 1 Using a low tariff and a control cable connection Settings made by the end user Setting function Particularly econom ical Average For increased com fort Target temperature 45 C 55 C 65 C Time...

Страница 18: ...fort Target temperature 45 C 55 C 65 C Time programming Low tariff LT ECO High tariff HT Frost protection Low tariff LT Comfort High tariff HT up to 12 00 ECO High tariff HT after 12 00 Frost pro tec...

Страница 19: ...h a fixed electricity tariff Settings made by the end user Setting function Average For increased com fort Target temperature 45 C 55 C 65 C Time programming From 23 00 to 11 00 Frost protection From...

Страница 20: ...ncy The immersion heater can be switched on as required Exception The air temperature lies outside the range between 7 C and 35 C In this case operation of the back up heater is permitted C End user l...

Страница 21: ...290841_00 aroSTOR Operating instructions 21 Setting level Values Unit Increment select explana tion Factory set ting Min Max BA CK UP ELEC BACKP ELEC BACKP LAN GUAGE LAN GUAGE 16 available languages E...

Страница 22: ......

Страница 23: ......

Страница 24: ...1 6188 671 Tel 01 6064 380 Tehni ki odjel 01 6188 673 Fax 01 6188 669 info vaillant hr www vaillant hr These instructions or parts thereof are protected by copyright and may be reproduced or distribut...

Отзывы: