7
Water pipe connection
-
The water flow through this machine needs to be driven by an appended water pump
(Prepared by the user). The recommended pump specification-flux is shown on the
product specification and Max. lift
≥
10m;
-
Pipe length between heat pump and swimming pool should not be longer than 10m.
Electric connection
-
Wiring must be handled by a professional technician according to the circuit diagram as
following.
-
Connect the heat pump to appropriate power supply and the voltage should comply with
the rated voltage of each model stated on the specification.
-
Make sure the machine is ground well.
-
Always put leakage protector according to the local code for wiring (leakage operating
current
≤
30mA).
-
Protect the circuit with a suitable circuit breaker or fuse (as it is shown in table on page 9)
Noted: The drawing is just for demonstration, and layout of the pipes for reference.
Содержание Rapid RH25L
Страница 35: ...33 Version H38W 130110...