background image

 

 

 

Figure 200 Rubber Flapper Check Valve 

 

 

INTRODUCTION 

This  manual  will  provide  the  information  to 
properly  install,  operate  and  maintain  the  valve 
to ensure a long service life.  The GA Industries 
Figure  200  Rubber  Flapper  Check  Valve  is 
designed  to  provide  years  of  dependable 
operation.  This manual will provide you with the 
information  needed  to  properly  install  and 
maintain the valve and to ensure a long service 
life.   
 
The valve is of the swing check type utilizing an 
angled  seat  and  fully  encapsulated,  resilient 
disc.    It  opens  to  allow  fluid  flow  in  the  forward 
direction  and  closes  automatically  to  prevent 
flow in the reverse direction.  
 
The  Figure  200  can  handle  a  wide  range  of 
fluids  including  those  containing  suspended 
solids.    The  valve

s  size,  flow  direction, 

maximum working pressure, and series number 
are  cast  on  the  valve  body  or  stamped  on  the 
nameplate.  
 

CAUTION 

Do not use valve for line

 

testing at pressures 

higher

 

than nameplate rating or

 

damage to valve 

may occur. 

 
Th

e  “Maximum  Working  Pressure”  is  the  non

-

shock 

pressure rating of the valve at 150˚ F. The 

valve  is  not  intended  as  an  isolation  valve  for 
line  testing  at  pressures  higher  than  the  valve 
rating. 
 

RECEIVING AND STORAGE 

Inspect  valves  upon  receipt  for  damage  in 
shipment.  Unload  all  valves  carefully  to  the 
ground  without  dropping.    Do  not  allow  lifting 
slings or chains to contact the backflow actuator  
or  visual  position  indicator  (if  provided).      Use 
eye bolts or rods through flange bolt holes to lift 
large valves.  
 
Valves should remain crated, clean and dry until 
installed to avoid weather related damage.   For 
storage longer than six months, apply a thin coat 
of approved lubricant to the flexible disc.  
 
 

 
 
Do  not  remove  flange  protectors  until  ready  to 
install  or  expose  flexible  disc  to  sunlight  or 
ozone for an extended period.   
 

DESCRIPTION OF OPERATION

 

The  valve  is  designed  to  automatically  prevent 
reverse flow.  During forward flow conditions, the 
movement of the fluid forces the disc to the open 
position  allowing  100%  unrestricted  flow  area 
through  the  valve.  Upon  flow  reversal,  the  disc 
automatically  returns  to  the  closed  position  to 
prevent 

reverse 

flow. 

 

 

 

Figure 1 

 

VALVE CONSTRUCTION 

The  standard  GA  Industries  Figure  200  Rubber 
Flapper  Check  Valve  is  constructed  of  rugged 
ductile iron with a reinforced rubber flexible disc. 
See the specific Materials List submitted for the 
order  if  other  than  standard  construction.  The 
disc  is  the  only  moving  part  assuring  long  life 
with  minimal  maintenance.  The  body  (1)  is 
flanged  for  connection  to  the  pipeline  with  an 

Item  Description 

Standard Material 

Body 

Ductile Iron 

Cover 

Ductile Iron 

Flexible Disc 

Buna-N Rubber Encapsulated Steel 

Gasket 

Buna-N 

Cover Bolt 

Stainless Steel 

Отзывы: