background image

 

 

 

Disassemble the valve only as far as needed to 
replace damaged or worn parts. 
 
First  ensure  there  is  no  pressure  within  the 
valve.    Refer  to  Page  5  for  parts  location  and 
identification.    
 
Remove the cover bolts (13) and lift off cover (2) 
with  float  and  linkage  attached.    It  may  be 
necessary to pry the cover off.  Be careful not to 
damage  or  lose  the  cover  O-ring  (14)  unless 
being replaced. 
 
Remove the spring pin (21) connecting the lever 
arm  to  the  cage  (3).    Remove  the  seat  (4)  from 
the cage and remove the  plug (5).  Remove the 
cage  O-ring  (16)  and  renewable  seat  (15)  from 
the seat.   
 
The float ball (12) is secured to the float rod (10) 
by Loctite 263 and the hex nut (20).  Loosen the 
hex  nut  (20)  and  apply  heat  (approx.  550F)  to 
the connection while unscrewing the float ball by 
hand.  (If replacing the float ball, it may be more 
practical  to  replace  both  the  float  ball  and  the 
float rod.) Be careful not to lose the lock washer 
(24).   
 
The  float  hood  (11)  is  attached  to  the  float  ball 
(12) by a nylon cap screw (25) and lock washer 
(24).  The cap screw is secured by Loctite 380.    
 
Inspect  all  parts  for  wear  and  damage.    Minor 
scratches  and  dents  in  the  float  are  normal.  
Replace the float if water is detected inside of it.   
Replace damaged parts. 
 

REASSEMBLY 

Clean  all  parts  especially  seating  and  sealing 
surfaces before reassembling valve.  Worn parts 
should be replaced during re-assembly. 
 
Install  plug  (5)  in  seat  (4),  lubricate  and  install 
cage O-ring (16) and renewable seat (15) in seat 
(4).    Thread  cage  (3)  with  plug  and  seat  into 
cover (2) and tighten.   
 
Thread  orifice  button  (8)  all  the  way  into  lever 
arm (7) and install hex nut (22) and lock washer 
(23)  but  do  not  tighten.    Connect  the  lever  arm 
(7) to the cage (3) using spring pin (21).    
 
Adjust the orifice button (8) so that the lever arm 
(7)  is  parallel  to  the  cover  (2)  when  it  is  gently 
resting  on  the  plug  (5)  in  the  closed  position. 
Secure by tightening hex nut (8). 

Install  hex  nut  (20)  and  lock  washer  (24)  onto 
end  of  float  rod  (10).    Apply  Loctite  263  to  the 
threads on the float rod (10) and screw float ball 
(12) onto float rod (10).  Tighten hex nut (20).  
 
Install  lock  washer  (24)  onto  cap  screw  (25). 
Apply  Loctite  380  to  cap  screw  (25)  insert 
through  center  hole  in  float  hood,  screw  onto 
float ball (12) and tighten.  
 
Verify free movement of linkage mechanism and 
that  the  orifice  button  (8)  presses  against  the 
plug  (5)  when  it  is  closed  and  pulls  away  from 
the plug when it in the fully open position. 
 
Lubricate and place O-ring (14) in cover (2) and 
carefully place cover (2) on body (1) ensuring O-
ring  is  retained.    Install  the  cover  bolts  (13) and 
tighten in an alternating pattern.   
 
Carefully  introduce  pressure  and  check  for 
leaks.  
 

BACKFLUSHING INSTRUCTIONS 
 

Follow all local cross-connection and safety 

codes and regulations! 

 
To determine if a GA Industries sewage air valve 
needs cleaning or backflushing: 

  Close  the  inlet  isolating  valve  then  slowly 

open the ½” flushing ball valve (if installed) 
or  slowly  remove  the  pipe  plug  at  the  top 
of air valve to relieve internal pressure.  

  Open t

he 1” blow off ball valve (if installed) 

or  remove  the  pipe  plug  near  the  bottom.  
Liquid  should  freely  drain  from  the  valve 
body.  If it does not, then the valve is likely 
in need of cleaning or backflushing. 

 
To  clean  a  GA  Industries  sewage  air  release 
valve equipped with backflushing attachments:  

  Close  the  inlet  isolating  valve  and  then 

slowly  open  the  ½”  flushing  valve  to 
relieve internal pressure. 

  Open the 

1” blow off valve 

  Conne

ct  the  ½”  flushing  valve  to  a 

pressurized  source  of  clean  water  using 
the  rubber  hose  provided  with  the 
backflushing attachments.  

  Introduce  flushing  water  until  liquid  runs 

freely from the blow off valve. 

  Shut  off  and  disconnect  the  supply  of 

clean  water  and  close  the  blow  off  and 
flushing valves. 

 