![VAF instruments PEM2 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/vaf-instruments/pem2/pem2_technical-manual_3147871009.webp)
9
6.3 INSTALLATION OF THE PEM2 TOUCH SCREEN
1. Install the PEM2 touch screen in a control cabinet or control panel in the ECR or on the bridge,
where it will be free as possible from moisture, large fluctuations of temperature and particularly of
vibration shock. Also influences such as large magnetic fields caused by transformers, relays or
electromagnets must be avoided.
2. All cable connections should be made using cables as specified in section 6.4.
3. Connect the RS485 Modbus cable from the stator control box and 24VDC power supply to the
backside of the PEM2 touch screen in accordance with Figure 4 and Figure 5.
1 24VDC power supply connector
2 COM2, 5-Pin terminal for data input via RS485 Modbus cable
6 COM1, 9-Pin female for data output/transfer to additional PEM2 touch screen
Figure 4 – Power supply and communication ports at backside of PEM2 touch screen