![VAF instruments PEM2 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/vaf-instruments/pem2/pem2_technical-manual_3147871013.webp)
13
6.4 CABLE SPECIFICATIONS
Specification for the input, output and power supply cables connected to the PEM2 touch screen.
T-Sense
Stator
Stator control box
PEM2
Touch screen
display
IC-10
IC-03
IC-01
IC-02
115 / 230 VAC
24 VDC
IC-09
PEM2
Touch screen
display
IC-10
24 VDC
IC-09
Figure 7 – Specification of input and output cables at the stator control box and PEM2 touch screens
Cable specification:
IC-01
Integrated antenna cable 5m, VAF supply
IC-02
Integrated stator cable 5m, VAF supply
IC-03
Power supply (115 / 230 VAC) cable, 3 x 1,5 mm
2
IC-09
Power supply (24 VDC) cable, 2 x 0,75 mm
2
IC-10
Modbus connection cable, 2 x 2 x 0,75 mm
2
twisted pair, individually screened, braid shielded
Remark:
When a TT-Sense
®
Thrust & Torque sensor is installed it can be connected in the same
way as above mentioned T-Sense
®
equipment.
Содержание PEM2
Страница 23: ...23 17 DRAWINGS Drawing 1 0897 1056...
Страница 24: ...24 Drawing 2 0815 2003...
Страница 25: ...25 Drawing 3 0815 2004...
Страница 26: ...26 Drawing 4 0815 2014...
Страница 27: ...27 Drawing 5 0815 2008...
Страница 28: ...28 Drawing 6 0815 2013...
Страница 32: ...32 Revision 0616 Chapter 1 1 warning added Pictures photos numbered and section links added...