  Installation 

  

4

  

5

  Installation 

Before installing your new mixer, flush 
through the pipework to ensure removal 
of debris, turn off the water supply.
      

 Warning!

  Please check for any 

hidden cables and pipes before drilling 
holes.
Position the seat and mark the 3 fixing 
holes, remove the seat and drill the 3 x 
12mm holes to the required depth.

Insert the expansion bolts into the holes. 
Slide the seat over the studs followed 
by  the 3 washers and nuts. Use the 
adjusting screws to level the seat, when 
satisfied with the level finally tighten 
down the bolts. 

Connect the inlet pipes to the seat with 
the hot on the left and cold on the right.

Nut

Washer

Seat

Bolts

Adjusting 

screw

Bolts

Hot inlet

Cold inlet

Seat

Front

Finish the floor covering down to a 
diameter of 78mm.

Remove the 2 screws and pull out 
the safety cover.

Insert the main body assembly into 
the seat, tighten the fastening plate, 
and cover with the escutcheon. 

Seat

78mm

Safety 

cover

Screws

Seat

Escutcheon

Fastening 

plate

Floor

Содержание Origins

Страница 1: ...ibility for any forms lost in the post and returns by registered means is therefore recommended Under this guarantee which is non transferable Vado will at its option repair or replace free of charge any product or replacement part found to be defective The guarantee does not extend to any consequential loss or damage After repair or replacement the relevant guarantee period will be calculated fro...

Страница 2: ...ater Fittings Regulations 1999 Schedule 2 Section 6 G15 13 2 Before making any inlet pipe connections all supply pipes MUST be thoroughly flushed to remove debris Failure to do so could result in damage or low flow from the mixer unit Water Supply Water Fittings Regulations 1999 Schedule 2 Section 4 G13 1 The fitting of isolating valves to the inlet feeds is advised for ease of maintenance Please ...

Страница 3: ...crease the flow of water Shower holder Operating Specifications Minimum operating pressure 3 bar Maximum operating pressure 5 bar 251mm 997mm 1095mm 850mm 80mm 60mm Min 115mm 191mm 79mm 93mm 755mm 54mm 90mm 74mm Showerhead Place one of the rubber washers into the cone end of the hose and screw to the Showerhead Place the second rubber washer into the other end of the hose and attach it to the mixe...

Страница 4: ...at over the studs followed by the 3 washers and nuts Use the adjusting screws to level the seat when satisfied with the level finally tighten down the bolts Connect the inlet pipes to the seat with the hot on the left and cold on the right Nut Washer Seat Bolts Adjusting screw Bolts Hot inlet Cold inlet Seat Front Finish the floor covering down to a diameter of 78mm Remove the 2 screws and pull ou...

Отзывы: