Installation
4
5
Temperature resetting
The valve has been factory set under balance pressures and hot water supply at 65° C.
When your specific operating conditions are significantly different from the above, the
temperature of the water may vary from the setting.
When the difference is too great, you can adjust the calibration of the valve to suit
individual requirements of the installation:
Select 38° C or the arrow on the handle and check the temperature of the water being
delivered to the outlet with a thermometer.
If the temperature is unacceptable proceed to reset the calibration as follows:
Remove the temperature control handle by unscrewing and removing the lever, using
the supplied hexagonal key loosen the grub screw and pull off the handle (do not
remove the plastic stop ring).
Turn the spline of the valve clockwise to decrease the temperature and anti-clockwise
to increase the temperature until 38° is achieved.
Ensure that the stop on the stop ring is at 12 o’clock and replace the handle with the
temperature override button also pointing at 12 o’clock being careful not to turn the
spline of the valve.
The valve setting is now calibrated to suit your requirements.
Secure the handle and replace the lever.
Before installing your new mixer, flush through the pipework to ensure removal of
debris, turn off the water supply.
Prepare the wall with 2 flush ½” connectors at 150mm centres. Connect the water
supply to the inlet pipes. The hot water should be connected to the left hand pipe.
Screw on the 2 offset connectors followed by the covers.
Place a filter/washer in each of the locking nuts on the valve and screw onto the
connectors, some adjustment can be made to the offset connectors to align the
centres and level up the valve.
Note:
The valve must be connected to rigid pipework for support as there are no
backnuts or fixing holes.
Control
handle
Temperature
override button
Shower outlet
Locking nuts
Fiilter/washer
Cover
Offset connector
Filter/washer
Cover
Temperature
control
Temperature
override button
Temperature
control handle
Lever
Stop ring
Valve
Splines
Stop