VADO celsius Скачать руководство пользователя страница 2

  Important - please read

  

2

  

7

Please read these instructions carefully before starting installation and keep for future 
reference.
Remove all packaging and check the product for missing parts or damage before 
starting installation.
Any alterations made to this product and fittings may infringe water regulations and 
will invalidate the guarantee.
The installation must comply with all Local/National Water Supply Authority 
Regulations/Byelaws and Building and Plumbing (UK:BS6700) Regulations.
We strongly recommend that you use a qualified and registered plumber.

  General installation

Thermostatic Valves

This mixer valve is suitable for any water system. Where instantaneous heaters are used, 
the flow of hot water sufficient to start and go on burning must reach the minimum 
flow required – as specified by the heater manufacturer. 
These fittings are mixing devices and therefore water supplies must be reasonably 
balanced.
Where connections are made to the mains cold water supply, WRC approved single 
check valves must be fitted to both hot and cold inlets. This is a stated requirement of 
Water Supply (Water Fittings) Regulations 1999 Schedule 2, Section 6 G15.13.2
Before making any inlet pipe connections, all supply pipes MUST be thoroughly 
flushed to remove debris. Failure to do so could result in damage or low flow from the 
mixer unit. Water Supply (Water Fittings) Regulations 1999 Schedule 2 Section 4 G13.1
The fitting of isolating valves to the inlet feeds is advised for ease of maintenance.
Please take great care when installing this mixer not to damage its surface.
Operating pressures (on hot and cold line) should be kept as balanced as possible in 
order to assure optimum efficiency.
Note: When pressure is higher than 5 bar a pressure reducer is required to be fitted 
before the valve.
Please note if installing in an enclosed environment, access should be left for servicing 
and maintenance. No costs relating to inadequate access can be accepted.

  Care of the mixer

Our products are finished to the highest standard and due care needs to be taken to 
ensure their looks are retained.
We recommend cleaning all products with a soft damp cloth ONLY and advise strongly 
against the use of ALL cleaning products i.e. powders and liquids.
If the above instructions are not followed this will invalidate your guarantee in the 
event of a problem occurring.

  Maintenance - continued

This thermostatic valve is fitted with a double filtering facility. Filters are fitted on the 
water inlets and on the thermostatic cartridge.
Depending on the water quality, filters may become dirty, causing reduced flow and 
inefficient working of the valve.
Shut off the water supply to both inlets at the isolating valves.

Inlet Filters.

Undo both locking nuts at the back of the valve and remove from the wall. Pull out 
the filter/washer, rinse in water to remove the dirt, and then soak them in vinegar or 
descaling agent. 

Cartridge Filters

To clean the filters, you must first remove the cartridge from the housing.
Removing the Cartridge
1. Remove the handle (see temperature resetting).
2. Unscrew the grubscrew on the underside of the body and pull out the cartridge.
3. Clean the filters by rinsing them in water to remove the dirt and soaking them in 
vinegar or descaling agent. 
4. Before reassembling the cartridge, clean its housing with a wet cloth and  grease the 
‘O’ rings on the cartridge. 
5. Reassemble the cartridge into the body aligning up the hole in the cartridge with 
the grubscrew, then place the plastic stop ring onto the cartridge with the stop at the 
12 o’clock position.
6. Make sure everything is tight and secure and turn on the water supply at the 
isolating valves.
7. Now check the water temperature to ensure you are happy with it.
8. Ensure that the stop on the stop ring is at 12 o’clock and replace the handle with the 
temperature override button also pointing at 12 o’clock being careful not to turn the 
spline of the valve.     
9. Secure the handle and replace the lever.

Содержание celsius

Страница 1: ...d returns by registered means is therefore recommended Under this guarantee which is non transferable Vado will at its option repair or replace free of charge any product or replacement part found to be defective The guarantee does not extend to any consequential loss or damage After repair or replacement the relevant guarantee period will be calculated from the original date of purchase The relev...

Страница 2: ...icing and maintenance No costs relating to inadequate access can be accepted Care of the mixer Our products are finished to the highest standard and due care needs to be taken to ensure their looks are retained We recommend cleaning all products with a soft damp cloth ONLY and advise strongly against the use of ALL cleaning products i e powders and liquids If the above instructions are not followe...

Страница 3: ...water as there is a potential for delivery of hot water 3 Remove temperature control handle refer to instruction leaflet and temperature stop ring essential 4 With shower in the on position replace temperature handle on thermostatic valve ensure temperature stop ring has been removed 5 Turn temp handle fully anti clockwise until stop point is reached and can be turned no further please ensure that...

Страница 4: ...stop on the stop ring is at 12 o clock and replace the handle with the temperature override button also pointing at 12 o clock being careful not to turn the spline of the valve The valve setting is now calibrated to suit your requirements Secure the handle and replace the lever Before installing your new mixer flush through the pipework to ensure removal of debris turn off the water supply Prepare...