Installation - Offset connectors
Before installing your new mixer, flush through the pipe work to ensure removal of
debris, turn off the water supply.
Note:
Make sure that the valve is positioned to allow room for the riser rail to be
fitted later (see dimensions on page 6).
Prepare the wall with 2 flush ½” connectors at 150mm centres. Connect the water
supply to the inlet pipes. The hot water should be connected to the left hand pipe.
Using PTFE tape screw on the 2 offset connectors followed by the covers.
Place a rubber filter/washer in each of the locking nuts on the valve and screw onto
the connectors, some adjustment can be made to the offset connectors to align the
centres and level up the valve.
Note:
The valve must be connected to rigid pipe work for support.
Cover
Locking nuts
Rubber filter/washer
Riser rail
connection
Cold
Hot
Offset connector
Offset connector
½”
connector
Note:
There are two options for installing your valve, using offset connectors
(below) or quick fit connectors (see page 13).
b4
b5
b6
x 2
1
2
3
Installation - Quick guide