13
01.03.2017
STR 300S
- The Low-lift position is now
set!
1d.
Basic settings Drilling unit
Setting of low-lift position for the drilling unit.
Lift the drilling unit with the yellow circuit to
the desired low-lift height.
- Press Low-lift.
- Enter the current scale value
(10.0).
Current
scale value.
After the configuration has been complet-
ed, the ground level will be equal to 0,
above ground will be minus and below will
be positive (in the example next to this
SystemDisc is therefore approx. 1
cm above the ground).
The activation time indicates
how long the depth setting for SystemDisc
is active in the run menu.
- Lift SystemDisc to the intended low-lift
position.
- Press
- Enter current scale value.
- Lower SystemDisc to the intended work
ing depth.
- Press
- Enter current scale value.
- Finished!
Current scale
value.
E-Contr
ol