Quick-Connect CCU HE100 Installation and User Guide 341-789 Rev. B                                                                            Page 8 of 12 

FCC, ICES-003 Compliance and CE Declaration of Conformity  

For Vaddio Quick-Connect CCU and EZIM CCU products 

 
 
 

FCC Part 15 Compliance 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to 
Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful 
interference when the equipment is operated in a commercial environment. This equipment generates, uses, 
and can radiate radio frequency energy and, if not installed and used in accordance with the instruction 
manual, may cause harmful interference to radio communications. Operation of this equipment in a 
residential area is likely to cause harmful interference in which case the user will be required to correct the 
interference at his/her own expense. 

Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This 
device must accept any interference including interference that may cause undesired operation of the device. 

Changes or modifications not expressly approved by Vaddio can affect emission compliance and could void 
the user’s authority to operate this equipment. 

 

ICES-003 Compliance 

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set 
out in the Radio Interference Regulations of the Canadian Department of Communications.   

Le présent appareil numérique n’emet pas de bruits radioélectriques dépassant les limites applicables aux 
appareils numeriques de la classe A préscrites dans le Règlement sur le brouillage radioélectrique édicte par 
le ministère des Communications du Canada. 

 

 

European Compliance 

This product has been evaluated for Electromagnetic Compatibility under the standards for Emissions and 
Immunity and meets the requirements for E4 environment.  This product complies with Class A (E4 
environment). In a domestic environment this product may cause radio interference in which case the user 
may be required to take adequate measures. 

Standard(s) To Which Conformity Is Declared: 

 

EMC Directive

 89/336/EEC 

EN 55022A

  

 

Conducted and Radiated Emissions 

EN 55024 

 

Electromagnetic Compatibility - Immunity

 

EN 61000-4-2

    

Electrostatic Discharge Requirements 

EN 61000-4-3

    

Radiated Electromagnetic Field Requirement 

EN 61000-4-4

    

Electrical Fast Transients / Burst Requirements 

EN 61000-4-5 

    

Surge Requirements 

EN 61000-4-6

   

Conducted Immunity Requirements 

EN 61000-4-8

   

Power Frequency Magnetic Field Requirements 

EN 61000-4-11

   

Voltage Dips, Interrupts and Fluctuations Requirements 

 

 

Содержание WALLVIEW CCU HE100

Страница 1: ...es including Tally illumination on the camera which allows the presenter to know which camera is live as well as Genlock delivered to the camera over CAT 5 INTENDED USE Before installing the Vaddio WallVIEW CCU Camera System please read the entire manual thoroughly All Vaddio camera systems are designed for use indoors Outdoor operation is not recommended has not been tested and could damage the c...

Страница 2: ...uick Connect CCU System uses a Cat 5 all 4 pairs for power to ensure the motors receive the required current to operate properly The Video Cat 5 cable uses all four pairs for video The RS 232 Cat 5 provides communication to the camera for CCU and PTZ control and G L where applicable to the camera These Cat 5 cables can be run up to 500 152 4m See Appendix 1 for wiring and pin out information NOTE ...

Страница 3: ...nto microprocessor memory When lit backlit blue SPDT switch the scene is activated To store a scene the user adjusts the controls and touches and holds the scene button down until the button blinks Detail The Detail control sharpens or softens objects in the frame Red Blue Gain Controls The Red and Blue Gain encoders adjust the red and blue gain of the signal when AWB is disengaged AWB The Automat...

Страница 4: ...a differential amplifier to a receiver at the EZIM CCU The G L gain adjustment is on the EZIM CCU or the receive side of the signal Camera Feature Switches The QCCU interface has an 8 position dip switch on the rear panel to allow future functionality Switch 2 needs to be in the UP position for the AW HE100 to function properly Y Gain Adjusts Y Gain and allows the user to fine tune the video signa...

Страница 5: ...sing four dry wall anchors MOUNTING INSTRUCTIONS Step 1 After determining the optimum location of the camera system mark locations for the four screw holes and cable pass thru vertical oval Install the drywall mounts and cut the hole for the cable pass thru At this point do not install the Wall Mount Step 2 Connect the 25 pin cable to the EZIM CCU Next mount the EZIM CCU and break out cable in the...

Страница 6: ... of control and operation of the cameras the RS 232 controller control system or joystick should be powered on after the camera Setting Up the AW HE Video Format and Output Settings The CCU system is capable of accessing the HE 100s internal settings for format 1080 59 94i 720 59 94 480i etc and output mode YPbPr RGB Y C Once the camera and CCU are powered up the configurations can be set The proc...

Страница 7: ...2 to 55mm Horizontal Viewing Angle 5 1 to 60 degrees 16 9 3 8 to 47 degrees 4 3 Pan Tilt Angle 175 to 175 degrees Pan 40 to 210 degrees Tilt Quick Connect CCU Interface QCCU Connectors Power Connector 5 5mm OD x 2 5mm ID Power RJ 45 Supplies 36V to EZCamera Interface Module Regulator Control In RJ 45 Accepts RS 232 from ProductionVIEW or other non daisy chain control systems Control Out RJ 45 Pass...

Страница 8: ... user s authority to operate this equipment ICES 003 Compliance This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le présent appareil numérique n emet pas de bruits radioélectriques dépassant les limites applicables aux appareils numeriques de la class...

Страница 9: ... 3 Not Used 4 Not Used 5 Not Used 6 GND 7 RXD from TXD 8 TXD to RXD RS 232 G L OUT Connector RJ 45 Pin Signal RS 232 1 Not Used 2 Not Used 3 Not Used 4 G L 5 G L GND 6 GND 7 RXD from TXD 8 TXD to RXD Video Connector RJ 45 Pin Signal SD HD 1 CVBS CVBS 2 CVBS GND CVBS GND 3 Y Y 4 C PB 5 C GND PB GND 6 Y GND Y GND 7 Not Used PR 8 Not Used PR 12345678 12345678 12345678 12345678 300 200 POWER 36V 2 78A...

Страница 10: ...Connector Pins Signal 1 CVBS GND 14 CVBS 2 G L GND 15 G L 3 NC 16 GND IN 4 TXD IN 17 RXD IN 5 NC 18 NC 6 NC 19 NC 7 GND PR 20 PR 8 GND C PB 21 C PB 9 GND Y Y 22 Y Y 10 GND PWR 23 GND PWR 11 GND PWR 24 12V PWR 12 12V PWR 25 12V PWR 13 12V PWR 12345678 12345678 12345678 POWER EZIM CCU VIDEO G L GAIN RS 232 IN G L IN Genlock Gain Adjustment Genlock Gain is set at the factory to the 3 o clock position...

Страница 11: ... and describe the reason for repairs or returns as well as the date of purchase and proof of purchase Include your assigned RMA number in all correspondence with Vaddio Write your assigned RMA number on the shipping label of the box when returning the product Please see Vaddio s website for current RMA policies and procedures Voided warranty The warranty does not apply if the original serial numbe...

Страница 12: ...63 971 4464 www vaddio com 2008 Vaddio All Rights Reserved Reproduction in whole or in part without written permission is prohibited Specifications and pricing subject to change Vaddio Quick Connect HSDS Quick Connect EZIM ProductionVIEW PreVIEW EZCamera and PowerRite are registered trademarks of Vaddio All other trademarks are property of their respective owners Document Number 341 789 Rev B ...