API and Programming Language 

 

       
+--------------------------------------------------------------------------+ 
|                 Vaddio ProductionVIEW HD-SDI MV                          | 
+--------------------------------------------------------------------------+ 
| ?         - This Menu                                                    | 
+------------------------ System Access -----------------------------------+ 
|Power      x- Power(On/Off)            |SysMode    x- (Manual/Auto)       | 
|ProgIn     x- Program (1-6,7-LSG,8-PIP)|Preset     x- Go to Preset(1-12)  | 
|PrevIn     x- Preview (1-6,7-LSG,8-PIP)|Store      x- Store Preset(1-12)  | 
|Camera     x- Switch to Camera(1-6)    |Take        - Take Button         | 
|DspCams     - List connected cameras   |Version     - Firmware Version    | 
|SaveConfig  - Manual Config Save       |ResetVideo  - Re-Load Video config| 
|Rescan      - Rescan cameras           |HomeButton x- Home Button(On,Off) | 
|SerialEcho x- Echo Serial (On/Off)     |                                  | 
|Config      - List Config Settings     |JSD70      x- On/Off/Timer(0-255) | 
+--------------- Camera ----------------+----------------------------------+ 
|Move     x,x- (Up/Down/Stop/Left/Right),Value                             | 
|Zoom     x,x- (In/Out/Stop),Value      |Home        - Home Camera         | 
+--------------------- Touch Screen Configuration--------------------------+ 
|WBtn xxddvvvvhhhhVVVVHHHH - Set button touch screen limits                | 
|     xx - Button Index (0x00-0x2f)                                        | 
|     dd - Button ID 0x3c:take,0x16-0x1b:preview 1-6,0x24-0x2f:preset 1-12 | 
|                    0x39:wipe,0x3a:cut,0x3b:fade                          | 
|     vvvv - Vertical coordinate lower limit                               | 
|     hhhh - Horizontal coordinate lower limit                             | 
|     VVVV - Vertical coordinate upper limit                               | 
|     HHHH - Horizontal coordinate upper limit                             | 
|RBtn xx - Read button touch screen limits record                          | 
|     xx - Button Index (0x00-0x2f)                                        | 
+-------------------------------------------------------------------------- 

Note: The Touch Screen Configuration read and write commands are used only for diagnostics by Vaddio 
Engineers to verify Touch Screen table parameters. 
 
 
 

Appendix 3: Command Structure Definitions 

 

Command Parameters 

Description

Camera Camera 

[9](cr) 

Select indicated camera (1-6) 

Config 

Config(cr) 

Display system configuration 

DspCams 

DspCams(cr) 

Display cameras connected(and Port) 

Home Home(cr) 

Home 

Camera 

HomeButton HomeButton On/Off(cr) 

Enable/Disable Home Button on Joystick 

JSD70 

JSD70 On/Off/[cr] 

Special Joystick processing for Sony D70 Camera 

Move Move(Up/Down/Left/Right/Stop)[,9](cr) Move 

camera 

Power 

Power On/Off(cr) 

Power system On/Off 

Preset 

Preset [9](cr) 

Select indicated preset (1-12) 

PrevIn 

PrevIn [9](cr) 

Select Preview input(1-6) 

ProgIn 

ProgIn [9](cr) 

Select Program input(1-6) 

Rescan 

Rescan(cr) 

Initiate Camera scan 

ResetVideo 

ResetVideo(cr) 

Re-Load Video Configuration 

SaveConfig SaveConfig(cr) 

Saves configuration of all console settings 

SerialEcho SerialEcho 

On/Off(cr) 

Serial Echo On/Off 

Store 

Store [9](cr) 

Store indicated preset on the current input source(1-138) 

SysMode 

SysMode Auto/Manual(cr) 

System Access automatic/Manual 

Take Take(cr) 

Initiate 

Transition 

Version Version(cr) 

Display 

System Version information 

Zoom 

Zoom (in/Out/Stop)[,9](cr) 

Zoom Camera, optional speed (1-7) 

 

 
 
Compliance and CE Declaration of Conformity  

Содержание PRODUCTIONView HD-SDI MV

Страница 1: ...EW HD SDI MV HD SDI Camera Control Console with Integrated Multiviewer Touch Screen Control Option Multi View Control Panel Layout Options and Expanded I O Capabilities Part Number 999 5655 000 North...

Страница 2: ...ProductionVIEW HD SDI MV ProductionVIEW HD SDI MV Manual Document Number 342 0318 Rev B Page 2 of 36 Inside Front Cover Blank...

Страница 3: ...ch camera input can have up to 12 stored video thumbnails of each preset camera shot These video thumbnail images provide an easy way to identify and recall preset camera positions The new Multi View...

Страница 4: ...ey want controlled Each camera input can have up to 12 stored video thumbnails of each preset camera shot These video thumbnail images provide an easy way to identify and recall preset camera position...

Страница 5: ...video resolution and the outputs have user configurable discrete video resolution settings See the specifications on page 27 for additional information on all of the resolutions supported Graphic Ins...

Страница 6: ...e operating the device please read the entire manual thoroughly The system was designed built and tested for use indoors and with the provided power supply and cabling The use of a power supply other...

Страница 7: ...DVI D Adapter Cable 10ft 3m One 1 DVD ROM with templates and sample graphics for Lower Screen Graphics Documentation For 999 5655 001 the International version unpack and identify the following parts...

Страница 8: ...k Transition Speed allows a wipe or crossfade mix to be adjusted up to 4 seconds in duration 6 Take Button Pressing the Take button switches the input selected from Preview to Program in single bus mo...

Страница 9: ...YCbCr color space depending on the resolution chosen in the menu When using the optional Vaddio TeleTouch Touch Screen Controller a HDMI to DVI D Adapter Cable included is used to connect to the Vaddi...

Страница 10: ...ons for video output resolution for the PROGRAM OUTPUT Press the arrow down button to the appropriate resolution that is compatible with your video monitor and press the SELECT Button Press the CANCEL...

Страница 11: ...Slot Card for the HD 30 HD22 HD 20 HD 19 and HD 18 expected HD SDI SDI cable distances are approximately as follows Resolutions SMPTE STD Cable Distances 720p 59 94 50 SMPTE 292M Max Length 754 543 f...

Страница 12: ...232 Note LCD Monitor displays the HD SDI Multiview Preview image HD SDI HD SDI HD SDI HDMI to DVI D Cable Note LCD Monitor displays the HD SDI Preview image Note LCD Monitor displays the HDMI Multivi...

Страница 13: ...is required to be stored up to 12 total positions per PTZ camera A non flashing preset button has a location stored but can be overwritten Select Follows Preview When Select Follows Preview is activa...

Страница 14: ...ton Changing Transition Speed Both the Mix and Wipe effects can be adjusted from 01 to 4 seconds by adjusting the Transition Speed knob which is located above the Mix button Transitions in Dual Bus Mo...

Страница 15: ...button is pressed Pressing the lower left PIP button will allow the LSG controls to decrease when either button is pressed Note This feature does not work in Dual Bus mode LSG in Dual Bus Mode In Dual...

Страница 16: ...IEW HD SDI MV to automatically switch between camera inputs and preset camera positions In this mode no operator is required The mats and sensors can be placed in locations such as podiums white board...

Страница 17: ...Step 1 To use the Multiviewer and TeleTouch Touch Screen Controller connect the main RS 232 port DB 9 F of the ProductionVIEW HD SDI MV to the RS 232 port of the TeleTouch Monitor with the cable prov...

Страница 18: ...chosen for Program or Preview To operate the ProductionVIEW HD SDI MV with the TeleTouch Touch Screen Monitor Plug in all the sources PTZ Cameras Video Whiteboard PC etc Try to get the sources at the...

Страница 19: ...recall To exit touch and don t hold a video input window General Specifications Optional TeleTouch HD Touch Screen LCD Monitors Feature TeleTouch 22 TeleTouch 18 5 Part Numbers 999 5520 022 Worldwide...

Страница 20: ...ts all inputs outputs and video processor Start Video Output Menu Select Video Output Menu Program Output HD 1080p 59 94Hz HD 1080p 50Hz HD 1080i 59 94Hz HD 1080i 50Hz HD 720p 59 94Hz HD 720p 50Hz SD...

Страница 21: ...t 01 12 Assigns camera preset 1 through 12 as Default Preset on the default camera default is 01 Def Idle Rtn Default Idle Return Position Automatic Mode only using an external trigger such as a StepV...

Страница 22: ...ng follows the Preview bus selection immediately transferring joystick and camera control directly to the camera selected on the Preview bus On is default NOTE This function only works in Single Bus M...

Страница 23: ...m Ctrl or CCU Port 01 Select method Direct Cam Ctrl or CCU Port 02 Select method Direct Cam Ctrl or CCU Port 03 Select method Direct Cam Ctrl or CCU Port 04 Select method Direct Cam Ctrl or CCU Port 0...

Страница 24: ...settle time there is a greater chance that a blue screen will appear on the Program output when the video is switched quickly and repeatedly In most applications this will not be an issue In Single Bu...

Страница 25: ...Window to the left side of the multiviewer screen Preview Position Right places the Preview Window to the Right side of the multiviewer screen The Program Window is placed in the opposite position of...

Страница 26: ...eneral Resolutions One 1 RJ 45 Female for Camera RS 232 Preview Multiviewer Out One 1 BNC Female HD SDI or SD SDI Resolutions Two 2 HDMI Female Connectors for Multiviewer HDMI Female x 2 Use one 1 HDM...

Страница 27: ...720p 50 720p 59 94 1080p 60 1080p 59 94 1080p 30 1080p 25 1080p 50 1080i59 94 fields s 1080i50 fields s 525i 29 97 625i 25 720p 25 720p 30 720p 50 720p 59 94 1080p 60 1080p 59 94 1080p 30 1080p 25 10...

Страница 28: ...see Pg 27 Two 2 HDMI Preview or Multiviewer Output HD SDI or SD SDI Same resolution on the BNC and both HDMI Preview Outputs see Pg 27 Program Output One 1 BNC Program Output HD SDI or SD SDI Same res...

Страница 29: ...abling With ProductionVIEW HD SDI MV all cabling configurations are home run wiring configurations Each Channel will auto configure the input channel for control of the camera attached Vaddio uses sim...

Страница 30: ...mits record xx Button Index 0x00 0x2f Note The Touch Screen Configuration read and write commands are used only for diagnostics by Vaddio Engineers to verify Touch Screen table parameters Appendix 3 C...

Страница 31: ...ications not expressly approved by Vaddio can affect emission compliance and could void the user s authority to operate this equipment ICES 003 Compliance This digital apparatus does not exceed the Cl...

Страница 32: ...e reason for repairs or returns as well as the date of purchase and proof of purchase Include your assigned RMA number in all correspondence with Vaddio Write your assigned RMA number on the outside o...

Страница 33: ...ProductionVIEW HD SDI MV ProductionVIEW HD SDI MV Manual Document Number 342 0318 Rev B Page 33 of 36 Notes...

Страница 34: ...ProductionVIEW HD SDI MV ProductionVIEW HD SDI MV Manual Document Number 342 0318 Rev B Page 34 of 36...

Страница 35: ...ProductionVIEW HD SDI MV ProductionVIEW HD SDI MV Manual Document Number 342 0318 Rev B Page 35 of 36 Back Inside Cover Blank...

Страница 36: ...014 Vaddio All Rights Reserved Reproduction in whole or in part without written permission is prohibited Specifications and pricing are subject to change without notice Vaddio ProductionVIEW TeleTouch...

Отзывы: