Option: Using the PC to MicDock Accessory Cable:
The GroupSTATION has a Premium 3’ (.91m) 4x4 Interface Cable PC to Dock accessory cable that combines the
Ethernet, HDMI, VGA, and USB cables into a single fan-out assembly to simplify cable management between the
MicDock and PC.
Image: PC to MicDock Cable Accessory
Step 6: Initial System Power Up
Once the PC is on and connected properly, plug the Camera/Sound Bar’s power supply’s AC cord into an AC wall
outlet. The unit will initialize and the OSD will display “Initializing” and prepare for operational use. The green
LED next to power button will light up.
When the system is finished initializing, the OSD will display the
IP
a
MAC
addresses for 10 seconds, then it
will show the VoIP IP address and Proxy Status for ten more seconds and time-out.
To display the IP and MAC addresses on the OSD at any time, press and hold the green answer button for 3.0 seconds
and the IP / MAC addresses will be displayed for 10 seconds and the VoIP address and Proxy Status will be displayed for
10 more seconds and the shut off.
It is most probably a good idea to write the addresses down. Otherwise, the default IP address of the
GroupSTATION is 169.254.1.1 and can be accessed via its internal web pages. Always involve the IT
department personnel for interfacing with any LAN/WAN. The network professionals will know how to set-up the
IP addresses in Static or DHCP modes as well as the VoIP functionality. Reinvention of the wheel isn’t required.
Image: Press and Hold Multifunction Buttons (PHMB)
There are three (3) PHMBs on the MicDock that have dual
functions. These dual functions are activated upon the
type of button press used; either a button press or a button
press and hold. Each of these buttons has an LED by it
and they are as follows:
1) Answer (Send) Button:
a.
A button press
answers inbound calls from VoIP or
USB, or it sends a dialed number to the VoIP PBX.
b.
Press and hold
for 5.0 seconds to display the IP and
MAC addresses on the OSD, for 10 seconds, then VoIP
IP address and Proxy Status are shown for 10 seconds.
2) Hang-up (Disconnect Button):
a.
A button press
disconnects a VoIP call. The Red LED
flashes once to indicate the call was terminated.
b.
Press and hold
the red Hang-up button for 5.0 seconds
for a Factory Reset,. The system will provide a prompt
on the monitor. When the prompt is answered the
system will begin to reset, please don’t interrupt a reset.
3) On/Off
Power
Button
.
a.
A button press
turns the system on. The green LED is illuminated when the system is on.
b.
Press and hold
the Power button for 3.0 seconds and the system will enter Standby Mode. In the off position, USB
audio/video ins and outs as well as VoIP functions are disabled and unit is in Standby. Standby Mode is indicated on
the OSD.