25mm
barrel union
25mm barrel union
25mm Y-Strainer
Solid level base
25mm
isolation
valve
25mm
swing
check
valve
100mm
House wall
VFB-APC
Recommended
150mm
VFB-MSU25
25mm isolation
valve
To house
Discharge pipe
min 25mm
25mm isolation
valve
Mains pipe
min 25mm
From mains
Min 100mm
26
VADA FLOW BOSS
HORIZONTAL MULTISTAGE PUMP
VFB-HM110
INSTALLATION MANUAL
INSTALLATION
4. Connect the power lead to the power
outlet. Do not turn on.
a. If installing the Horizontal Multistage
Pump by itself, simply connect the
two supplied cords using the IEC socket
and plug.
b. If installing an VFB-APC or VFB-MSU25,
connect the IEC socket from the pump
to the IEC plug cord on the VFB-APC or
VFB-DSU.
Note:
Supply voltage that is outside the
limits specified can cause the motor to
overheat leading to overload tripping, reduced
component life or seriously damage pump,
voiding warranty.
Note:
For additional protection, the pump
must be supplied from an outlet protected by
a residual current device – RCD (also known
as an Electrical Leakage Circuit breaker –
ELCB) with a maximum rated residual current
of 30mA.
Note:
Do not use extension cords. This can
cause the voltage to drop.