TROUBLE SHOOTING GUIDE
Symptom
Remedy
Press the button and nothing happens
Make sure that the power is on and the unit is switched on.
Test that the power point is working by plugging in another appliance.
Check the connection to the button is correct.
The V30-RC runs but hot water does not reach the tap.
Check that the hot water system is on and the water is heating.
Check that the pipes connecting the V30-RC are connected to the hot and cold points correctly.
Check that the pressures of the hot and cold systems are similar.
The V30-RC runs when the button has not been pressed.
Check the connection to the button is sound.
The V30-RC runs for the full four minutes but the hot water
is not at the tap.
Check that the hot water system is on and hot.
Check that the pipes connecting the V30-RC are connected to the hot and cold points respectively.
You have installed the V30-RC on a very large installation and the pipe system is longer than the
V30-RC is able to pump within the four-minute maximum run time.
The V30-RC runs and switches off but the water is not hot.
The cold water through the V30-RC may be inhibited, check that there are not any valves or fittings
that may be designed to allow flow in one direction only, between the V30-RC and the hot water
unit or tank. The water within the cold water line must be able to flow back towards the hot water
system. Some stop valves will not allow water to flow in reverse it will be necessary to remove or
replace these valves. Also check the in and out points on the V30-RC and ensure that the hot and
cold are correctly connected. Check that the unit is installed in the correct direction of flow
Hot water is in the cold line when the V30-RC has not been
operating.
Re check both hot and cold pressures are equal – a higher hot water pressure may allow some by
pass of hot water into the cold line when other cold taps are turned on
VADA - V30-RC
SERVICE
To avoid dangerous or fatal electrical shock hazard, turn
OFF power to motor and remove plug from power outlet
before working on pump or motor.
WARRANTY
You have purchased a quality product from Reece Australia. This
product is covered by a 12 month warranty. This warranty covers faults
in the product construction, material and assembly. Faulty products
will be repaired or exchanged free of charge. Faulty items become our
property.
This warranty does not include faults caused by
•
Unsuitable or improper use
•
Incorrect installation
•
Normal wear and tear
•
Inadequate or complete lack of maintenance
•
Chemical, electrochemical or electrical influences
To the maximum extent permitted by law, Reece excludes all warranties
other than those set out above. In the event of a warranty claim, we
will replace or repair defective products, or pay for the cost of having
defective products repaired or replaced, but will not be liable for any
injury to any person, damage to any property, any indirect or
consequential loss, or in any other respect.
Pump should only be serviced by qualified
personnel. For best results, use only genuine
service parts.
Disclaimer:
Products in this specification manual must by regulation be installed by licenced and registered trades people. The manufacturer / distributor reserves the
right to vary specifications or delete models from their range without prior notification. Dimensions and set-outs listed are correct at time of publication
however the manufacturer distributor takes no responsibility for printing errors.