VADA V30-RC Скачать руководство пользователя страница 6

TROUBLE SHOOTING GUIDE

Symptom

Remedy

Press the button and nothing happens

Make sure that the power is on and the unit is switched on. 

Test that the power point is working by plugging in another appliance.

Check the connection to the button is correct. 

The V30-RC runs but hot water does not reach the tap.

Check that the hot water system is on and  the water is heating.

Check that the pipes connecting the V30-RC are connected to the hot and cold points correctly.

Check that the pressures of the hot and cold systems are similar.

The V30-RC runs when the button has not been pressed.

Check the connection to the button is sound.

The V30-RC runs for the full four minutes but the hot water 

is not at the tap.

Check that the hot water system is on and hot.

Check that the pipes connecting the V30-RC are connected to the hot and cold points respectively.

You have installed the V30-RC on a very large installation and the pipe system is longer than the 

V30-RC is able to pump within the four-minute maximum run time.

The V30-RC runs and switches off but the water is not hot.

The cold water through the V30-RC may be inhibited, check that there are not any valves or fittings 

that may be designed to allow flow in one direction only, between the V30-RC and the hot water 

unit or tank. The water within the cold water line must be able to flow back towards the hot water 

system. Some stop valves will not allow water to flow in reverse it will be necessary to remove or 

replace these valves. Also check the in and out points on the V30-RC and ensure that the hot and 

cold are correctly connected. Check that the unit is installed in the correct direction of flow 

Hot water is in the cold line when the V30-RC has not been 

operating.

Re check both hot and cold pressures are equal – a higher hot water pressure may allow some by 

pass of hot water into the cold line when other cold taps are turned on

VADA - V30-RC

SERVICE

To avoid dangerous or fatal electrical shock hazard, turn 

OFF power to motor and remove plug from power outlet 

before working on pump or motor.

WARRANTY

You have purchased a quality product from Reece Australia. This 

product is covered by a 12 month warranty. This warranty covers faults 

in the product construction, material and assembly. Faulty products 

will be repaired or exchanged free of charge. Faulty items become our 

property.

This warranty does not include faults caused by

• 

Unsuitable or improper use

• 

Incorrect installation

• 

Normal wear and tear

• 

Inadequate or complete lack of maintenance

• 

Chemical, electrochemical or electrical influences

To the maximum extent permitted by law, Reece excludes all warranties 

other than those set out above. In the event of a warranty claim, we 

will replace or repair defective products, or pay for the cost of having 

defective products repaired or replaced, but will not be liable for any 

injury to any person, damage to any property, any indirect or 

consequential loss, or in any other respect.

Pump should only be serviced by qualified 

personnel. For best results, use only genuine 

service parts. 

Disclaimer:

Products in this specification manual must by regulation be installed by licenced and registered trades people. The manufacturer / distributor reserves the 

right to vary specifications or delete models from their range without prior notification. Dimensions and set-outs listed are correct at time of publication 

however the manufacturer distributor takes no responsibility for printing errors.

Отзывы: