The pump is designed to be used with clean water 

in a residential application. Do not use it with 

alternative fluids, specifically abrasive, corrosive 

or explosive fluids. Do not install or operate your 

pump in an explosive environment or near 

combustible matter. Do not pump hydrocarbons 

with this pump.

Incorrectly installed or tested equipment may fail, 

causing severe injury or property damage.

To avoid burns when handling the motor, let it cool 

for at least 20 minutes before trying to work on it. 

A thermal overload switch protects the motor from 

heat damage during operation. 

If the supply cord is damaged, it must be replaced 

by the manufacturer, it’s service agent or similarly 

qualified persons in order to avoid a hazard 

Children should be supervised to ensure they do 

not play with the appliance

The pump must be supplied through a residual cur-

rent device (RCD) having a rated residual operating 

current not exceeding 30mA.

Only qualified, licensed personnel should install 

pump. The electrical installation shall be in 

accordance with the national wiring rules (AS/NZS 

3000)

The pump operator must be provided with this 

manual. This must be read before and during opera-

tion.

These instructions are a guide only. Users not 

familiar with pumping equipment should seek 

advice from people experienced in pump equipment 

and installation.

Single-phase motors are provided with built-in 

thermal overload protection. Motors must connect 

the earth wire before use. 

The pump is electrically connected. Ensure that it 

is isolated from electrical supply during installation 

and any subsequent service work.

This appliance is not intended for use by persons 

(including children) with reduced physical, sensory 

or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervi-

sion or instruction concerning use of the appliance 

by a person responsible for their safety. 

CONSTRUCTION

Pump Head Body

Celcon GC25 POM

Motor Body

Cast Alloy

Impeller

Celcon GC25 POM

Impeller Shaft

Alumina Ceramic

Thrust Rings

Alumina Ceramic

Bearings

PTFE

O-Ring Seals

EPDM

APPLICATIONS

The V30-RC is an ‘on-demand’ recirculating pump. The pump 

reduces water wastage by returning cold water to the hot water unit 

while waiting for hot water to come through the tap.

USAGE LIMITATIONS

• 

Type of liquid: clean water with no suspended abrasive material

• 

Maximum liquid temperature: 60

O

C

• 

Maximum total head: 8m

• 

Maximum flowrate: 15 l/min

VADA - V30-RC