Troubleshooting
When the Home Base is unable to achieve the required vacuum level, either in the Home Base itself, the bags or the containers, one of the following
light indicators codes may appear:
Lights are blinking
This means:
Possible solutions:
Inner LED light ring
+
Blue indicator light
The proper vacuum level in the
Home Base cannot be reached.
The system has automatically
switched off.
• Check if there are any items sticking out of the Home Base that might
prevent the lid from closing completely.
• Check if there is anything crossing the seal.
• If so, remove the items and try the process again.
Middle LED light ring
+
Blue indicator light
It takes too long for the proper
vacuum level in the Home Base
to be reached. The system has
automatically switched off.
• Remove the lid seal and carefully clean it.
• Closely inspect the seal for small damages, holes or ruptures.
• If the seal is intact and clean, re-install it and try the system again.
Outer and inner LED light
ring
+
Blue indicator light
The proper vacuum level in the
container or bag cannot be
reached.
The system has automatically
switched off.
• Check all connections between the Home Base and the container or bag.
• Check if there are any items sticking out of the container that might prevent
the lid from closing completely.
• Check if there is anything crossing the seal.
• Firmly press the lid back on the container and try again.
Outer and middle LED light
ring
+
Blue indicator light
It takes too long for the proper
vacuum level in the container
or bag to be reached.
The system has automatically
switched off.
• Remove the container seal and carefully clean it.
• Closely inspect the container seal for small damages, holes or ruptures.
• If the seal is intact and clean, re-install it and try the system again.
• Check the seal on the bag to see if it is properly closed.
• Check if there are no holes or tears in the bag.
This means:
Possible solutions:
Pump does not switch on
+
Light does not switch on
There is no electrical connection
between the lid magnet and steel
plate on the Home Base.
The system did not switch on.
• Make sure the Home Base is properly connected to a power outlet.
• Remove any items that might prevent the lid to close completely.
• Clean the magnet on the lid and the steel plate on the Home Base.
• Make sure the Home Base is not in standby mode. See page 18 for
instructions regarding starting and stopping the standby mode.
In case the suggested tips do not help or the problem persists, please visit www.vacuvita.com or email us at [email protected].
+
+
+
+
+
www.vacuvita.com
Vacuvita manual 25
Cleaning the container
- Wash the container and the lid by using water and mild dishwasher
soap.
-
The base of the container is top-rack dishwasher safe. The lid should
only be cleaned manually to avoid damage.
Do not scrub the seal or the valve using scouring
materials as this may damage it and prevent the container
from sealing
- Thoroughly dry the container and the lid before using it again.
Cleaning and re-installing the seal
- Flip the lid upside down. You will notice a
small recess on the inner rim. Place your
finger in the indent and gently pull out the
seal.
-
Clean the seal using water and a mild soap.
Do not put the seal in the dishwasher.
Do not use sharp objects to remove or reinstall the seal.
- Wipe the seal dry before re-installing it in the lid.
- To re-install the seal, locate the flat side of the seal. Keeping the seal
flat side down, start by placing it one of the corners and pressing it
down, working your way along the sides.
Cleaning the valve
-
Grab the valve on top of the container by the
flaps and pull it out of the lid.
- Clean the valve using water and mild soap.
- To re-install the valve, place it in the middle
of the lid, aligning it to the indent. The nipple
of the valve should go through the hole.
Grab the nipple from the other side of the lid
and pull it gently to secure it in place.