Troubleshooting

When the Home Base is unable to achieve the required vacuum level, either in the Home Base itself, the bags or the containers, one of the following 
light indicators codes may appear: 

Lights are blinking

This means:

Possible solutions:

Inner LED light ring           
            +
Blue indicator light

The proper vacuum level in the 
Home Base cannot be reached.
The system has automatically 
switched off.

•  Check if there are any items sticking out of the Home Base that might  

prevent the lid from closing completely.

•  Check if there is anything crossing the seal.
•  If so, remove the items and try the process again.

Middle LED light ring 
            +
Blue indicator light

It takes too long for the proper 
vacuum level in the Home Base  
to be reached. The system has 
automatically switched off.

•  Remove the lid seal and carefully clean it.
•  Closely inspect the seal for small damages, holes or ruptures.
•  If the seal is intact and clean, re-install it and try the system again.

Outer and inner LED light  
ring 
            +
Blue indicator light

The proper vacuum level in the 
container or bag cannot be 
reached.
The system has automatically 
switched off.

•  Check all connections between the Home Base and the container or bag.
•  Check if there are any items sticking out of the container that might prevent 

the lid from closing completely.

•  Check if there is anything crossing the seal.
•  Firmly press the lid back on the container and try again.

Outer and middle LED light 
ring 
            +
Blue indicator light

It takes too long for the proper 
vacuum level in the container  
or bag to be reached. 
The system has automatically 
switched off.

•  Remove the container seal and carefully clean it.
•  Closely inspect the container seal for small damages, holes or ruptures.
•  If the seal is intact and clean, re-install it and try the system again. 
•  Check the seal on the bag to see if it is properly closed.
•  Check if there are no holes or tears in the bag. 

This means:

Possible solutions:

Pump does not switch on 
            +
Light does not switch on

There is no electrical connection 
between the lid magnet and steel 
plate on the Home Base.
The system did not switch on.

•  Make sure the Home Base is properly connected to a power outlet. 
•  Remove any items that might prevent the lid to close completely.
•  Clean the magnet on the lid and the steel plate on the Home Base.
 •  Make sure the Home Base is not in standby mode. See page 18 for 

instructions regarding starting and stopping the standby mode. 

In case the suggested tips do not help or the problem persists, please visit www.vacuvita.com or email us at [email protected].

+

+

+

+

+

www.vacuvita.com 

Vacuvita manual   25

Cleaning the container

-   Wash the container and the lid by using water and mild dishwasher 

soap. 

 The base of the container is top-rack dishwasher safe. The lid should 
only be cleaned manually to avoid damage.

Do not scrub the seal or the valve using scouring 
materials as this may damage it and prevent the container 
from sealing

-   Thoroughly dry the container and the lid before using it again.

Cleaning and re-installing the seal

-   Flip the lid upside down. You will notice a 

small recess on the inner rim. Place your 
finger in the indent and gently pull out the 
seal. 

 Clean the seal using water and a mild soap.

Do not put the seal in the dishwasher.
Do not use sharp objects to remove or reinstall the seal.

-   Wipe the seal dry before re-installing it in the lid.
-   To re-install the seal, locate the flat side of the seal. Keeping the seal 

flat side down, start by placing it one of the corners and pressing it 
down, working your way along the sides.  

Cleaning the valve

 Grab the valve on top of the container by the 
flaps and pull it out of the lid. 

-   Clean the valve using water and mild soap.
-   To re-install the valve, place it in the middle 

of the lid, aligning it to the indent. The nipple 
of the valve should go through the hole. 

 

Grab the nipple from the other side of the lid 
and pull it gently to secure it in place.

Содержание Home Base

Страница 1: ...www vacuvita com For Vacuvita Home Base vacuum containers and vacuum bags Manual quick reference guide...

Страница 2: ...your food within seconds The springs and dampers are perfectly balanced for smooth opening and one handed closing of the cover Creating a vacuum is as easy as closing the lid Your Vacuvita system can...

Страница 3: ...er the grill Important safety instructions Please carefully read this user manual before using this product and keep it for future reference When using your Vacuvita products always take basic precaut...

Страница 4: ...er Vacuvita products are not a substitute for refrigeration or freezing Perishables still need to be kept in the refrigerator or freezer Vacuum packaging is not a substitute for canning Always allow f...

Страница 5: ...picture Simply plug the free end of the vacuum tube in the Home Base and press the circular indicator LED light rings will light up when the vacuum tube is attached properly picture Quick check Vacuu...

Страница 6: ...18 Vacuum bags Using the Vacuvita Home Base 19 with vacuum bags Cleaning the vacuum adapter 20 Vacuum containers Using the Vacuvita Home Base 21 with vacuum containers How to scan your containers 22...

Страница 7: ...tomatically open the lid and release the vacuum 3 Blue indicator light 4 Home Base lid 5 Adapter socket with removable cap 6 Circular indicator LED light rings 7 Capacitive touch control to enable the...

Страница 8: ...he power plug from the wall socket In case of an emergency or system malfunction the vacuum can be released by pressing the emergency vacuum release switch Turn the Vacuvita Home Base so the back is f...

Страница 9: ...Insert the free side of the adapter hose into the vacuum socket The LED light rings will switch on below the Home Base lid Place the vacuum adapter on the marked area around the valve of the vacuum ba...

Страница 10: ...cleaned Do not use the bags for different raw products after each other Always apply proper hygienic precautions to prevent foodborne illness For an optimal vacuum process with liquids such as freshl...

Страница 11: ...injuries from exposure You can heat cooked foods such as leftovers in a Vacuvita bag using a microwave The bag should not be used to microwave raw foods Always open the bag prior to putting it in a mi...

Страница 12: ...ils Gently slide the filter back after cleaning SECTION A A SCALE 2 1 Cleaning or replacing the removable air filter Occasionally you may need to clean or replace the air filter on the outside of the...

Страница 13: ...losed Check if there are no holes or tears in the bag This means Possible solutions Pump does not switch on Light does not switch on There is no electrical connection between the lid magnet and steel...

Страница 14: ...his product with non Vacuvita parts or accessories Furthermore this Limited Warranty does not cover Acts of God such as fire flood hurricanes and tornadoes This Limited Warranty shall not be deemed to...

Страница 15: ...www vacuvita com Vacuvita B V Orionstraat 15 2516 AS The Hague The Netherlands Designed to suit your taste...

Отзывы: