VACUVENT VA Series Скачать руководство пользователя страница 4

Independent Valve Marketing (Pty) Ltd 

 

  

Engineering 

Page 4 of 18

 

VSS0203WD00  

GENERAL SPECIFICATION 

SCREWED – DN25 (1”), DN50 (2”)  

 

Figure 1- Overall Dimensions 

 

 

DN 

Model 

No. 

PN 

Weight 

Inch 

 

Psi  Inch  Inch 

Lbs 

025VA25  363  13.2 

3.8 

9.5 

025VA40  580  15.7 

3.8 

12.3 

050VA25  363  15.2 

4.8 

13.2 

050VA40  580  18.7 

4.8 

16.5 

Type:  

Double Orifice (Small and large orifice) with Anti-Shock Orifice Mechanism 
 

End Connection: 

Screwed BSP or NPT male 
 

Nominal Size 

DN25 (1”) and DN50 (2”) 
 

Model No’s 

See Table 
 

Operating Pressure 

PN25    

0.5 bar (7.2 psi) – 25 bar (363 psi) 

PN40    

0.5 bar (7.2 psi) – 40 bar (580 psi) 

 

Operating Temperature 

4

o

C (40

o

F) to 85

o

C (185

o

F) 

 

Acceptable Media: 

Potable or strained raw water 
 

Function: 

1.  High Volume Air Discharge for pipeline filling 
2.  Pressurized Air Discharge for air in filled pipeline 
3.  High volume Air Intake for pipeline draining 
4.  Anti-shock- surge dampening  

 

 

Содержание VA Series

Страница 1: ...AIR RELEASE AND VACUUM BREAK VALVES SERIES VA OWNER S MANUAL...

Страница 2: ...neral Specification 5 General Specification 6 Quality Control 10 General Description 10 Functional Testing and Overall Inspection 11 Corrosion Protection 11 Shipping 11 Installation Removal and Storag...

Страница 3: ...for the installation maintenance and general care required by the air valve to produce optimum results for the end user Your Vacuvent air valve should function flawlessly for many years as it is virtu...

Страница 4: ...all and large orifice with Anti Shock Orifice Mechanism End Connection Screwed BSP or NPT male Nominal Size DN25 1 and DN50 2 Model No s See Table Operating Pressure PN25 0 5 bar 7 2 psi 25 bar 363 ps...

Страница 5: ...d Connection Flanged for alignment to BS 4504 PN10 PN16 PN25 or PN40 SANS 1123 T1000 3 T1600 3 T2500 3 or T4000 3 ANSI B16 1 Class150 or ANSI B16 5 Class 300 Nominal Size DN150 and DN200 Model No s Se...

Страница 6: ...m End Connection Flanged for alignment to BS 4504 PN10 PN16 PN25 or PN40 SANS 1123 T1000 3 T1600 3 T2500 3 or T4000 3 ANSI B16 1 Class150 or ANSI B16 5 Class 300 Nominal Size DN150 and DN200 Model No...

Страница 7: ...Independent Valve Marketing Pty Ltd Engineering Page 7 of 18 VSS0203WD00...

Страница 8: ...Independent Valve Marketing Pty Ltd Engineering Page 8 of 18 VSS0203WD00...

Страница 9: ...Independent Valve Marketing Pty Ltd Engineering Page 9 of 18 VSS0203WD00...

Страница 10: ...re variance in pipelines Surge and water hammer will always be present in fluid transporting pipelines the intent of the Vacuvent air valve is to effectively manage the affects thereof in liquid trans...

Страница 11: ...eline under pressure Criteria Small orifice release of air up to working pressure Anti shock opening up to working pressure 5 Visual Inspection Purpose Ensure quality of the product Criteria No visibl...

Страница 12: ...cumulator facilitates the effective introduction of air into a draining pipeline If an accumulator is not used the incoming air may be swept away before effectively vented Figure 4 Air Valve Arrangeme...

Страница 13: ...ring the air valve firmly DO NOT USE A PIPE WRENCH ON THE AIR VALVE AND ON THE BARREL OF THE AIR VALVE THIS MAY RESULT IN DAMAGE TO THE COATING AND OR MECHNICAL DAMAGE TO THE AIR VALVE FLANGED TYPE Fl...

Страница 14: ...alculated by adding all the valves on that section Exhaust however is another matter and it s feasible in some instances to add all the anti shock capabilities for one section It s also important to e...

Страница 15: ...to protect the pipeline and seals from low pressure within the pipeline during draining or other pipeline disturbances e g pump trip One accepted method is to limit the internal pressure to 3 5 m P 5...

Страница 16: ...shock orifice item 2 through the upper float This discharge will be sufficient for the pressurised air to evacuate the valve and the pipeline This type of valve operation is validated by Surge Analys...

Страница 17: ...ove figure one can see the air accumulating in the valve with the pipeline under pressure generally only when small amounts of air enters the valve through the pressurized system again this operation...

Страница 18: ...one valve with its smart anti shock will fulfil the functions of several different valves without modification or ad ons CONTACT DETAILS Feel free to contact us regarding your Vacuvent valve should yo...

Отзывы: