VACUVENT VA Series Скачать руководство пользователя страница 3

Independent Valve Marketing (Pty) Ltd 

 

  

Engineering 

Page 3 of 18

 

VSS0203WD00  

INTRODUCTION 

Congratulations on your purchase of the Vacuvent Air Release and Vacuum Break Valve. This air 

valve is the product of years of development and attention to detail. Innovation and commitment to 

progress has yielded a new generation of air valve fit to carry the demands of modern pipelines. 

Vacuvent series VA air valves combine several features of different types of air valves into one 

compact unit. These reliable, sturdy and proudly made valves will ensure the safety of your pipeline 

for many problem free years. 

This manual is intended to give guidelines for the installation, maintenance and general care 

required by the air valve to produce optimum results for the end user. Your Vacuvent air valve 

should function flawlessly for many years as it is virtually maintenance free.  

This manual starts of by describing the valve specifications and the materials used in the air valve.  

Quality control assures that the valve is in good working condition from the corrosion protection to 

the pneumatic functions and the valve integrity. This section describes the measures taken to 

deliver a high quality valve. 

A general description of the valve function and purpose is included in this manual. 

General information regarding the details of quality testing and shipping is provided for the end user 

to feel reassured. 

This document is not intended to be used a design guide for the Vacuvent air release valve. 

 

 

 

Содержание VA Series

Страница 1: ...AIR RELEASE AND VACUUM BREAK VALVES SERIES VA OWNER S MANUAL...

Страница 2: ...neral Specification 5 General Specification 6 Quality Control 10 General Description 10 Functional Testing and Overall Inspection 11 Corrosion Protection 11 Shipping 11 Installation Removal and Storag...

Страница 3: ...for the installation maintenance and general care required by the air valve to produce optimum results for the end user Your Vacuvent air valve should function flawlessly for many years as it is virtu...

Страница 4: ...all and large orifice with Anti Shock Orifice Mechanism End Connection Screwed BSP or NPT male Nominal Size DN25 1 and DN50 2 Model No s See Table Operating Pressure PN25 0 5 bar 7 2 psi 25 bar 363 ps...

Страница 5: ...d Connection Flanged for alignment to BS 4504 PN10 PN16 PN25 or PN40 SANS 1123 T1000 3 T1600 3 T2500 3 or T4000 3 ANSI B16 1 Class150 or ANSI B16 5 Class 300 Nominal Size DN150 and DN200 Model No s Se...

Страница 6: ...m End Connection Flanged for alignment to BS 4504 PN10 PN16 PN25 or PN40 SANS 1123 T1000 3 T1600 3 T2500 3 or T4000 3 ANSI B16 1 Class150 or ANSI B16 5 Class 300 Nominal Size DN150 and DN200 Model No...

Страница 7: ...Independent Valve Marketing Pty Ltd Engineering Page 7 of 18 VSS0203WD00...

Страница 8: ...Independent Valve Marketing Pty Ltd Engineering Page 8 of 18 VSS0203WD00...

Страница 9: ...Independent Valve Marketing Pty Ltd Engineering Page 9 of 18 VSS0203WD00...

Страница 10: ...re variance in pipelines Surge and water hammer will always be present in fluid transporting pipelines the intent of the Vacuvent air valve is to effectively manage the affects thereof in liquid trans...

Страница 11: ...eline under pressure Criteria Small orifice release of air up to working pressure Anti shock opening up to working pressure 5 Visual Inspection Purpose Ensure quality of the product Criteria No visibl...

Страница 12: ...cumulator facilitates the effective introduction of air into a draining pipeline If an accumulator is not used the incoming air may be swept away before effectively vented Figure 4 Air Valve Arrangeme...

Страница 13: ...ring the air valve firmly DO NOT USE A PIPE WRENCH ON THE AIR VALVE AND ON THE BARREL OF THE AIR VALVE THIS MAY RESULT IN DAMAGE TO THE COATING AND OR MECHNICAL DAMAGE TO THE AIR VALVE FLANGED TYPE Fl...

Страница 14: ...alculated by adding all the valves on that section Exhaust however is another matter and it s feasible in some instances to add all the anti shock capabilities for one section It s also important to e...

Страница 15: ...to protect the pipeline and seals from low pressure within the pipeline during draining or other pipeline disturbances e g pump trip One accepted method is to limit the internal pressure to 3 5 m P 5...

Страница 16: ...shock orifice item 2 through the upper float This discharge will be sufficient for the pressurised air to evacuate the valve and the pipeline This type of valve operation is validated by Surge Analys...

Страница 17: ...ove figure one can see the air accumulating in the valve with the pipeline under pressure generally only when small amounts of air enters the valve through the pressurized system again this operation...

Страница 18: ...one valve with its smart anti shock will fulfil the functions of several different valves without modification or ad ons CONTACT DETAILS Feel free to contact us regarding your Vacuvent valve should yo...

Отзывы: