![vacuubrand MD 4 VARIO select Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/vacuubrand/md-4-vario-select/md-4-vario-select_instructions-for-use-manual_3206759059.webp)
page 59 of 68
20901106_EN_MD4_MV2_VARIO_select_V1.0_140818
fuse holder
➨
Unscrew the fuse holder using a slotted screw driver.
➨
Replace the defective fuse by a fuse of the same type (see “Technical
data”, pg. 25). Reassemble holder with fuse to the pump.
Replacing the device fuse
➨
Switch off the pump.
➨
Disconnect the electrical power cord
before un-
screwing the fuse holder.
Identify and eliminate the cause of failure before switch-