7
AUTO
LOW
HIGH
VACUUM
PUSH
PULSE
LOW
LOW
※
※
Turning on the power
Connect the power plug of the main body to 220V outlet, press the
power button to turn on the lamps on the control panel with the
signal sound. Lamps will turn on partially when the vacuum container
is not set properly or when the vacuum cap is not closed properly.
The blender function will not operate when the lamp is not on.
Even when the power is off, a small amount of electricity is flowing through
the product.
This switch puts power on suspend, but does not completely turn it off.
7.
If an error occurs without the operation being complete, the problem
may be due to lose seal. Tap the top of the vacuum valve in the main
part when the vacuum starts.
LOW
HIGH
PULSE
PUSH
LOW
HIGH
PULSE
PUSH
※
※
Speed Control
Turn the speed control dial clockwise to start the blender. The
blending speed increases by the ratio of turning the dial, and
decreases to a stop when the dial is turned the other way around.
(Lamp will flicker at various rates depending on the blending speed).
The blender will stop when you press Pulse button while controlling the
speed.
It will operate for a fixed period of time and stop automatically.
8.
PUSH
AUTO
LOW
HIGH
VACUUM
PULSE
※
Vacuum
When you press the vacuum button, it will automatically reach the
automatically set vacuum pressure. The lamp will flick during
vacuum action, and it will stop when you press the button again.
When an error occurs, the vacuum and pulse lamps will flicker
simultaneously with the buzzer sound, and this will be cancelled when you
press the power button again. Check the connection between vacuum
container and main body and the vacuum valve for trouble.
10.
PUSH
AUTO
LOW
HIGH
VACUUM
PULSE
※
Auto
When you press auto button, it will automatically carry out vacuum,
pulse, and blend functions in respective order and also automatically
stop without additional control of the user.
Lamps will flicker when the blender is running and stop when you
press the auto button again.
When an error occurs, the vacuum and pulse lamps will flicker
simultaneously with the buzzer sound, and this will be cancelled when you
press the power button again. Check the connection between vacuum
container and main body and the vacuum valve for trouble.
11.
PUSH
AUTO
LOW
HIGH
VACUUM
PULSE
(Dial's lamp will flicker at a fast rate).
Pulse
When you press the pulse button on the speed control dial, the
blender will instantly run at full power.
9.