50 • vacon
Description of parameters
Tel. +358 (0)201 2121 • Fax +358 (0)201 212 205
1530
Analogue
output
2
function
(2.3.2.1)
1531
Analogue output 2 filter time
(2.3.2.2)
1532
Analogue output 2 inversion
(2.3.2.3)
1533
Analogue output 2 minimum
(2.3.2.4)
1534
Analogue output 2 scale
(2.3.2.5)
See respective parameters
to 311 at
Analogue output 1
.
1535
Analogue
output
3
function
(2.3.3.1)
1536
Analogue output 3 filter time
(2.3.3.2)
1537
Analogue output 3 inversion
(2.3.3.3)
1538
Analogue output 3 minimum
(2.3.3.4)
1539
Analogue output 3 scale
(2.3.3.5)
See respective parameters
to 311 at
Analogue output 1
.
1540
Relay
output 1
inversion
(2.3.4.3)
1541
Relay
output 2
inversion
(2.3.5.3)
1542
Relay
output 3
inversion
(2.3.6.3)
If the values of these parameters = 0, no inversion of the respective relay output signal takes
place.
1544
Analogue input 1 supervision
(2.2.4)
1545
Analogue input 2 supervision
(2.2.10)
1546
Analogue input 3 supervision
(2.2.17)
The signal level of the respective analogue input is supervised if value 1 is given to this
parameter.
1549
Relay output 1, signal selection
(2.3.4.1)
1550
Relay output 2, signal selection
(2.3.5.1)
1551
Relay output 3, signal selection
(2.3.6.1)
1552
Relay output 4, signal selection
(2.3.7.1)
Connect the RO signal to the relay output of your choice with this parameter using the TTF
programming method. More information on the TTF method in Vacon All in One Application
manual. You will find the relay output signal contents on page 30.
1553
Relay
output 4
function
(2.3.7.2)
1554
Relay
output
4
inversion
(2.3.7.3)
See par. ID1540.
1555
Relay output 5, signal selection
(2.3.8.1)
See par. ID1549.
1556
Relay
output 5
function
(2.3.8.2)