Page 2 (15)
Vacon
I/O-expander board installation (Vacon CXS-range)
Vacon Plc
Tel:
+358-201 2121
Fax:
+358-201 212 205
Service:
+358-40-8371 150
E-mail:
[email protected]
http://www.vacon.com
1
GENERAL
Due to the compact frame size of the Vacon CXS series all I/O-expander boards need
to be installed in a separate box (Vacon CXSOPTBKIT), except the smaller, specifically
for Vacon CXS designed boards (Vacon CX104OPT, CX105OPT, CX107OPT,
CX108OPT). If ordered together with the option board these will be preinstalled.
1.1
Vacon CX100OPT
The available I/O can be increased by using the Vacon CX100OPT I/O-expander
board:
- 5 digital inputs (standard signals)
- 2 analogue inputs (standard signals)
- 3 relay outputs (standard signals)
- analogue output (programmable)
- thermistor input (can be directly connected to the motor
thermistors to monitor the motor temperature)
- encoder input
Typical use: Closed Loop Vector Control
1.2
Vacon CX101OPT
The available I/O can be increased by using the Vacon CX101OPT I/O-expander
board:
- 5 digital inputs (standard signals)
- relay output (standard signal)
- thermistor input (can be directly connected to the motor thermistors to monitor
the motor temperature)
Typical use: thermistor input required
1.3
Vacon CX102OPT
The available I/O can be increased by using the Vacon CX102OPT I/O-expander
board:
- 5 digital inputs (standard signals)
- 2 analogue inputs (standard signals)
- 3 relay outputs (standard signals)
- analogue output (programmable)
- thermistor input (can be directly connected to the motor thermistors to
monitor the motor temperature)
- encoder input
Typical use: Closed Loop Vector Control
1.4
Vacon CX103OPT
The available I/O can be increased by using the Vacon CX103OPT I/O-expander
board:
- 5 digital inputs (standard signals)
- 3 relay outputs (standard signals)
- analogue output (programmable)
- thermistor input (can be directly connected to the motor thermistors to monitor
the motor temperature)
Typical use: thermistor input and additional analogue output required