description of parameters
vacon
•
21
24-hour s358 (0)40 837 1150 • Email: [email protected]
2.3.1.8
Mechanical brake reaction time
Mechanical brake reaction time will hold the speed reference for the defined time by
this parameter. This hold time should be set according to the mechanical brake
reaction time (see
2.3.1.9
Maximum frequency brake closed
Output frequency does not exceed this value when mechanical brake is closed. When
modifying this parameter make sure that the brake release by frequency (see
parameter
Closing Brake Parameters (M2 -> G2.3.2)
2.3.2.1
Frequency limit closing
The output frequency limit for the brake closing. The run request signal needs to be
disabled to allow the signal to affect.
2.3.2.2 Closing
delay
The brake closing is delayed with defined time. If set to zero there is no delay between
the brake closing condition and the actual brake closing.