11
filter, see page 10.
3. Carefully slide foam sleeve filter down over the filter cage making sure the whole cage is covered.
(fig.2 & 3)
4. Replace the power head on to the container.
Cleaning Foam Sleeve Filter
1. With the removed power head in the upside down position, carefully remove foam sleeve filter. (fig.4)
2. Use a mild soap and water solution to wash foam sleeve filter and rinse with clean water. (fig.5)
3. Allow filter to air dry before installing and using again.
Instructions For Dust Bag Installation
1. Slide the cardboard collar opening firmly onto the vacuum port deflector until it stops against the
deflector wall.
2. Position the bag so that it is distributed around the inside of the tank.
3. Replace and secure the power head onto the tank.
4. FOR DRY PICK-UP ONLY.
Symptom
Possible Causes
Corrective Action
Vacuum will not operate
1) No power supply.
1) Check power supply – cord,
breakers, fuses.
2) Faulty power cord.
2) Unplug and check the power
cord. If damaged, have it repaired
by a professional.
3) Container full.
3) Empty container.
Dust comes out from motor cover. 1) The reusable cloth filter is missing
or damaged.
1) Attach or replace the reusable
cloth filter.
Reduced efficiency and
motor/speed vibration.
1) There is a blockage in the nozzle,
hose, or the vacuum inlets. Or the
reusable cloth filter is blocked by fine
dust.
1) Check nozzle, hose and inlets
for blockage. Take off the filter and
clean it. Or install new filter.
TROUBLESHOOTING
WARNING!
TO REDUCE THE RISK OF ELECTRIC SHOCK-UNPLUG BEFORE TROUBLESHOOTING
INSTALLING THE DUST COLLECTION BAG
Содержание VQ407S