Disconnect the power cord from the electrical outlet by unplugging it. DO
NOT disconnect by pulling on the cord.
▫
DO NOT immerse in water or spray directly with liquid.
▫
Check the Vacuum Chamber and Gasket, making sure they are clean and
free of debris. If needed, use a clean, damp cloth with mild soap.
a. Wipe the vacuum chamber clean.
b. Wipe the gasket clean.
c. Wipe the seal area clean.
▫
Do not store the VP800 outside. 65
°
to 75
°
recommended.
▫
DO NOT use any acetone-based or abrasive cleaners on the lid or other
plastic parts. Only clean lid with a damp cloth and mild soap.
Cleaning & Storage
Maintenance Kit
1. Exhaust Filter:
Spare filter; should be checked
every 6 -12 months. If the filter looks dirty or
saturated in oil; it will need to be changed. If
the filter looks clean; it is ok to put back into
the pump & motor assembly.
2.
Double Sided Tape:
Used for adhering the top
bar that holds the seal pad in the lid.
3.
15-Amp Fuses (2x):
Can be used for replacing
fuses located on the control transformer and
the cord receptacle. NSF models will have a
fuse on the seal transformer.
4.
Seal Wire:
Used to replace seal wire that spans
the length of the seal bar; should be replaced if
the wire shows heavy discoloration.
5.
Seal Tape:
Used to replace seal tape the
covers the seal wires; should be replaced if the
tape shows heavy discoloration, is torn, or is
starting to lose the adhesive.
6.
Oil Fill Bottle:
Used to fill pump with oil.
7. Hex/ Allen Wrench:
Used to removed tension
blocks that hold the seal wire to the base of
the seal bar.
8.
#1 Screwdriver:
Used to un-thread screws on
the cabinet of the machine and the screws to
move the chamber.
1
2
3
4
5
7
6
8
16
ARY, Inc. | 11880 College Blvd Suite 550 Overland Park, KS 66210 | www.VacMasterFresh.com | 800-821-7849
VP
800 Chamber Vacuum Sealer
|
User Guide